All categories
Compare Cart

A9D55432 - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 32A, C curve, 6000A/6kA, AC type, 300mA - Schneider Electric

Expected in 2-4 weeks EAN: 3606481157799
A9D55432 - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 32A, C curve, 6000A/6kA, AC type, 300mA - Schneider Electric - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 32A, C curve, 6000A/6kA, AC type, 300mA - Schneider Electric - 0
EAN: 3606481157799
A9D55432 - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 32A, C curve, 6000A/6kA, AC type, 300mA - Schneider Electric
238,78 € excl. VAT
291,31 € incl. VAT
Text About:
Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 32A, C curve, 6000A/6kA, AC type, 300mA - Schneider Electric
291,31 €
SPECIFICATIONS
Additional Information
curve C
Main
Range Acti9
sectioning ability Non se conformer à CEI 60947-1
name of the device iC60 RCBO
type of product or equipment Disjoncteur différentiel
differential sensitivity 300 mA
Product Name Acti9 iC60 RCBO
[ui] rated insulation voltage 500 V CA 50 Hz
number of poles protected 4
type of trigger Thermique-magnétique
Complementary
"no" connection 9 mm entre pôles
9 mm pitches 8
[ue] rated operational voltage 380...415 V CA 50 Hz
application Distribution
peak current 250 A
[ics] rated service breaking capacity 6000 A 100 % Icn à 380...415 V CA 50 Hz se conformer à EN/CEI 61009-2-1
6 kA 100 % Icu à 380...415 V CA 50 Hz se conformer à EN/CEI 60947-2
Handle front plate colour 86 mm
tightening torque 2 N.m
[uimp] rated impulse withstand voltage 4 kV
compatibility of distributors, combs, busbars Haut ou bas : oui
Bas : biconnect
in rated operational current 32 A
limiting class 1 se conformer à EN/CEI 61009-2-1
product weight 423 g
fully apparent cut Non
mode d'installation Encliquetable
electrical life 10000 cycle
connection mode Borne du type à cage haut ou bas1…35 mm² rigide
Borne du type à cage haut ou bas1…25 mm² souple
Borne du type à cage haut ou bas1…25 mm² flexible avec embout
mechanical endurance 20000 cycle
width (w) 72 mm
network frequency 50 Hz
Colour Blanc
delay Instantané
voltage indication Marche, arrêt, déclencheur sur défaut
position of the switchgear in the installation Départ
wire stripping length 12 mm pour haut ou bas connexion
depth 78 mm
differential technology Indépendant de la tension
mounting bracket Rail DIN
magnetic trip limit 5,,,10 x In
Network type Type AC
differential protection Intégrée
order type Par maneton
Poles description 4P
Environment
ip degree of protection IP40 (coffret de répartition) conforming to CEI 60529
IP20 conforming to CEI 60529
electromagnetic compatibility Tenue aux ondes 8/20 µs, 250 A se conformer à EN/CEI 61009-2-1
overvoltage category III se conformer à CEI 60364
standards EN/CEI 60947-2
EN/CEI 61009-2-1
quality labels KEMA-KEUR
IMQ
VDE
NF
relative humidity 95 % à 55 °C
operating temperature -25…40 °C
storage room temperature -40…70 °C
tropicalization 2
Recently viewed
238,78 € excl. VAT
291,31 € incl. VAT
Expected in 2-4 weeks