All categories
Compare Cart

A9D27232 - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 32A, C curve, 10000A/15kA, A-SI type, 30mA - Schneider Electric

Expected in 2-4 weeks
A9D27232 - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 32A, C curve, 10000A/15kA, A-SI type, 30mA - Schneider Electric - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 32A, C curve, 10000A/15kA, A-SI type, 30mA - Schneider Electric - 0
A9D27232 - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 32A, C curve, 10000A/15kA, A-SI type, 30mA - Schneider Electric
168,05 € excl. VAT
205,02 € incl. VAT
Text About:
Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 32A, C curve, 10000A/15kA, A-SI type, 30mA - Schneider Electric
205,02 €
SPECIFICATIONS
Additional Information
curve C
Main
Device short name iC60 RCBO
Device location in system Outgoer
Range Acti9
Earth-leakage protection class Type A-SI (Super Immunised)
Number of protected poles 2
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 30 mA
Product Name Acti9 iC60 RCBO
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 500 V AC 50 Hz
Complementary
9 mm pitches 4
[in] rated current 32 A
[ue] rated operational voltage 220...240 V AC 50 Hz
[ics] rated service breaking capacity 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Control type Toggle
Connection pitch 9 mm between poles
Handle front plate colour 86 mm
Product or component type Residual current breaker with overcurrent protection (RCBO)
tightening torque 2 N.m
[uimp] rated impulse withstand voltage 4 kV
Comb busbar and distribution block compatibility Top or bottom: YES
Bottom: biconnect
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid
Tunnel type terminal top or bottom 1…25 mm² flexible
Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Contact position indication No
Device application Distribution
width (w) 36 mm
network frequency 50 Hz
Colour White
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Net weight 273 g
wire stripping length 12 mm for top or bottom connection
Earth-leakage protection Integrated
Mounting support DIN rail
depth 78 mm
mechanical durability 20000 cycles
electrical durability 10000 cycles
magnetic trip limit 5...10 x In
Network type AC
Limitation class 3 conforming to EN/IEC 61009-2-1
residual current tripping technology Voltage independent
Surge current 3000 A
Suitability for isolation No conforming to IEC 60947-1
Poles description 2P
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP40 (distribution enclosure) conforming to IEC 60529
IP20 conforming to IEC 60529
ambient air temperature for operation -25…40 °C
electromagnetic compatibility 8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1
overvoltage category III conforming to IEC 60364
standards EN/IEC 60947-2
EN/IEC 61009-2-1
quality labels VDE
IMQ
NF
KEMA-KEUR
Tropicalisation 2
relative humidity 95 % at 55 °C
Recently viewed
168,05 € excl. VAT
205,02 € incl. VAT
Expected in 2-4 weeks