All categories
Compare Cart

56265 - residual current protection relay, VigiPacT RH21P, 30 mA or 300 mA, 440/525 VAC 50/60 Hz, front panel mounting - Schneider Electric

Expected in 2-4 weeks
56265 - residual current protection relay, VigiPacT RH21P, 30 mA or 300 mA, 440/525 VAC 50/60 Hz, front panel mounting - Schneider Electric - residual current protection relay, VigiPacT RH21P, 30 mA or 300 mA, 440/525 VAC 50/60 Hz, front panel mounting - Schneider Electric - 0
56265 - residual current protection relay, VigiPacT RH21P, 30 mA or 300 mA, 440/525 VAC 50/60 Hz, front panel mounting - Schneider Electric
351,90 € excl. VAT
429,31 € incl. VAT
Text About:
residual current protection relay, VigiPacT RH21P, 30 mA or 300 mA, 440/525 VAC 50/60 Hz, front panel mounting - Schneider Electric
429,31 €
SPECIFICATIONS
Main
Current sensors compatibility VigiPacT TOA earth leakage current sensor
VigiPacT A earth leakage current sensor
VigiPacT L earth leakage current sensor
Device short name RH21P
[ithe] thermal current under enclosure 8 A
Range VigiPacT
Earth-leakage protection class Type A
Earth-leakage sensitivity 0.03 A
0.3 A
Earth-leakage time delay Instantaneous for 0.03 A
Instantaneous for 0.3 A
Fixed 0.06 s for 0.3 A
Earthing system TN-S
TT
IT
Minimum load 10 mA at 12 V
Monitored distribution system 1000 V - AC at 50/60 Hz (maximum)
1000 V - AC at 400 Hz (maximum)
reset Manual reset
Relay application Protection relay
Residual earth-leakage sensitity adjustment type Adjustable 2 settings
Complementary
Handle front plate colour 72 mm
Product or component type Residual current protection relay
tightening torque Auxiliary power supply: 0.6 N.m
Fault: 0.6 N.m
Relay test and fault reset: 0.6 N.m
Sensor: 0.6 N.m
Voltage presence: 0.6 N.m
[uimp] rated impulse withstand voltage 8 kV
[us] rated supply voltage 440...525 V AC 50/60 Hz 70...110 %
Connections - terminals Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12
Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12
Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12
Fault: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12
Fault: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12
Fault: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12
Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12
Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12
Relay test and fault reset: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12
Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12
Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12
Sensor: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12
Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12
Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12
Voltage presence: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12
Cut-out dimensions 68 x 68 mm
type of measurement Earth fault current internal measurement, range: 80...100 %
Electrical shock protection class Class II
width (w) 72 mm
mechanical robustness Fire resistance conforming to IEC 60695-2-1
IK protection 2 joules: IK07 conforming to EN 50102
Vibrations 13.2...100 Hz: 0.7 g
Vibrations 2...13.2 Hz: +/- 1 mm
Ik degree of protection IK07 conforming to EN 50102
Net weight 0.3 kg
Monitoring Electronics (continuous)
Power supply (continuous)
Relay/sensor link (continuous)
wire stripping length Auxiliary power supply: 7 mm
Fault: 7 mm
Relay test and fault reset: 7 mm
Sensor: 7 mm
Voltage presence: 7 mm
Mounting support Front panel
depth 78 mm
Pollution degree 3 conforming to IEC 60664-1
Power consumption in va 4 VA
type of setting Selector
Tamperproof of settings Protected by sealable cover
Test function Local
Remote test
Environment
Ambient air temp for storage/transportation -55…85 °C
ip degree of protection IP40 on front face: conforming to EN/IEC 60529
IP30 on side parts: conforming to EN/IEC 60529
IP20 on connection terminals: conforming to EN/IEC 60529
ambient air temperature for operation -35…70 °C
electromagnetic compatibility Conducted and radiated emissions: , B, conforming to CISPR 11
Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6
Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2
High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5
Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4
Radiated susceptibility: , 3, conforming to IEC 61000-4-3
overvoltage category IV
relative humidity 95 % at 55 °C
Recently viewed
351,90 € excl. VAT
429,31 € incl. VAT
Expected in 2-4 weeks