SPECIFICATIONS
Main
Device short name Compact NS800N
Range ComPact
circuit breaker mounting mode Fixed
Neutral position Left
Protected poles description 4D
Product Name ComPact NS
Trip unit name Micrologic 5.0
Trip unit technology Electronic
Trip unit rating 800 A at 50 °C
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functions LSI
performance level N 50 kA 415 V AC
Complementary
[ii] instantaneous pick-up adjustment range Off
2...15 x In
[in] rated current 800 A at 50 °C
[ue] rated operational voltage 690 V AC 50/60 Hz
[ics] rated service breaking capacity 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[icw] rated short-time withstand current 19.2 kA 1 s conforming to IEC 60947-2
Control type Toggle
Rotary handle
depth (d) 147 mm
Product certifications ASEFA
ASTA
[ir] long-time protection pick-up adjustment range 0.4...1 x In
Connection pitch 70 mm
Handle front plate colour 327 mm
Product or component type Circuit breaker
[isd] short-time protection pick-up adjustment range 1.5...10 x Ir
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Auxiliary contact composition 1 NO/NC
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
[tsd] short-time delay adjustment range 0.1…0.4 s I²t=on
0…0.4 s I²t=off
Device application Distribution
width (w) 280 mm
network frequency 50/60 Hz
thermal memory 20 mn
Ik degree of protection IK07 conforming to EN 50102
Local signalling 4 LEDs (red) for fault indication
1 LED (yellow) for overload
power losses 15 W
long-time pick-up adjustment type ir (thermal protection) Adjustable 9 settings
Net weight 18 kg
long-time protection delay adjustment type tr Adjustable 9 settings
Downside connection Front
Earth-leakage protection Without
Mounting support Backplate
mechanical durability 10000 cycles
neutral protection setting No protection (3D)
0.5 x Ir (3D + N/2)
1 x Ir (4D)
electrical durability 2000 cycles at 690 V In
4000 cycles at 690 V In/2
5000 cycles at 440 V In
6000 cycles at 440 V In/2
Network type AC
instantaneous protection pick-up adjustment type ii Adjustable
Pollution degree 3 conforming to IEC 60947
short-time protection delay adjustment type tsd Adjustable
short-time protection pick-up adjustment type isd Adjustable 9 settings
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 4P
Upside connection Front
Utilisation category Category B
Protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Zone selective interlocking zsi Without
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
operating altitude 0...2000 m without derating
2000 m...5000 m with derating
Range of product ComPact NS630b...1600
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-2
relative humidity 0…95 %