SPECIFICATIONS
Main
Device short name Compact NS800L
Range ComPact
circuit breaker mounting mode Fixed
Protected poles description 3D
Product Name ComPact NS
Trip unit name Micrologic 5.0
Trip unit technology Electronic
Trip unit rating 800 A at 50 °C
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functions LSI
performance level L 150 kA 415 V AC
Complementary
[ii] instantaneous pick-up adjustment range Off
2...15 x In
[in] rated current 800 A at 50 °C
[ue] rated operational voltage 690 V AC 50/60 Hz
[ics] rated service breaking capacity 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
Rotary handle
depth (d) 147 mm
Product certifications ASTA
ASEFA
[ir] long-time protection pick-up adjustment range 0.4...1 x In
Connection pitch 70 mm
Handle front plate colour 327 mm
Product or component type Circuit breaker
[isd] short-time protection pick-up adjustment range 1.5...10 x Ir
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Auxiliary contact composition 1 NO/NC
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
[tsd] short-time delay adjustment range 0.1…0.4 s I²t=on
0…0.4 s I²t=off
Device application Distribution
width (w) 210 mm
network frequency 50/60 Hz
thermal memory 20 mn
Ik degree of protection IK07 conforming to EN 50102
Local signalling 4 LEDs (red) for fault indication
1 LED (yellow) for overload
power losses 20 W
long-time pick-up adjustment type ir (thermal protection) Adjustable 9 settings
Net weight 14 kg
long-time protection delay adjustment type tr Adjustable 9 settings
Downside connection Front
Earth-leakage protection Without
Mounting support Backplate
mechanical durability 10000 cycles
electrical durability 2000 cycles at 690 V In
3000 cycles at 690 V In/2
3000 cycles at 440 V In
4000 cycles at 440 V In/2
Network type AC
instantaneous protection pick-up adjustment type ii Adjustable
Pollution degree 3 conforming to IEC 60947
short-time protection delay adjustment type tsd Adjustable
short-time protection pick-up adjustment type isd Adjustable 9 settings
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 3P
Upside connection Front
Utilisation category Category A
Protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Zone selective interlocking zsi Without
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
operating altitude 0...2000 m without derating
2000 m...5000 m with derating
Range of product ComPact NS630b...1600
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-2
relative humidity 0…95 %