SPECIFICATIONS
Main
Range ComPacT
sectioning ability Oui
type of product or equipment Interrupteur-sectionneur
Product Name ComPacT INV
[ui] rated insulation voltage 750 V CA 50/60 Hz
visible cut Oui
Complementary
"no" connection 45 mm
[icm] rated short circuit making capacity 330 kA avec coupe-circuit de protection en amont 690 V CA à 50/60 Hz
50 kA sectionneur seulement 690 V CA à 50/60 Hz
[ie] rated operational current AC-21A: 400 A CA 50/60 Hz 220/240 V
AC-21A: 400 A CA 50/60 Hz 380/415 V
AC-21A: 400 A CA 50/60 Hz 440/480 V
AC-21A: 400 A CA 50/60 Hz 480 V NEMA
AC-21A: 400 A CA 50/60 Hz 500/525 V
AC-21A: 400 A CA 50/60 Hz 660/690 V
AC-22A: 400 A CA 50/60 Hz 220/240 V
AC-22A: 400 A CA 50/60 Hz 380/415 V
AC-22A: 400 A CA 50/60 Hz 440/480 V
AC-22A: 400 A CA 50/60 Hz 480 V NEMA
AC-22A: 400 A CA 50/60 Hz 500/525 V
AC-22A: 400 A CA 50/60 Hz 660/690 V
AC-23A: 400 A CA 50/60 Hz 220/240 V
AC-23A: 400 A CA 50/60 Hz 380/415 V
AC-23A: 400 A CA 50/60 Hz 440/480 V
AC-23A: 400 A CA 50/60 Hz 480 V NEMA
AC-23A: 400 A CA 50/60 Hz 500/525 V
AC-23A: 400 A CA 50/60 Hz 660/690 V
DC-21A: 400 A CC 125 V 2 pôles en série
DC-22A: 400 A CC 125 V 2 pôles en série
DC-23A: 400 A CC 125 V 2 pôles en série
[ue] rated operational voltage 250 V CC
690 V CA 50/60 Hz
[icw] rated short-time withstand current 11,5 kA pendant 3 s se conformer à CEI 60947-3
20 kA pendant 1s se conformer à CEI 60947-3
4 kA pendant 30 s se conformer à CEI 60947-3
4,9 kA pendant 20 s se conformer à CEI 60947-3
[ith] conventional thermal current 400 A à 60 °C
Handle colour Noire
Handle front plate colour 205 mm
[uimp] rated impulse withstand voltage 8 kV
mechanical life 10000 cycle
product weight 4,6 kg
fully apparent cut Oui
mode d'installation Fixe
electrical life AC-21A: 1000 cycle 440 V CA 50/60 Hz
AC-21A: 1000 cycle 500 V CA 50/60 Hz
AC-21A: 1000 cycle 690 V CA 50/60 Hz
AC-22A: 1000 cycle 440 V CA 50/60 Hz
AC-22A: 1000 cycle 500 V CA 50/60 Hz
AC-22A: 1000 cycle 690 V CA 50/60 Hz
AC-23A: 1000 cycle 440 V CA 50/60 Hz
AC-23A: 1000 cycle 500 V CA 50/60 Hz
AC-23A: 1000 cycle 690 V CA 50/60 Hz
DC-21A: 1000 cycle 125 V CC
DC-22A: 1000 cycle 125 V CC
DC-23A: 1000 cycle 125 V CC
width (w) 185 mm
network frequency 50/60 Hz
maximum power AC-23: 110 kW à 220/240 V CA 50/60 Hz
AC-23: 110 kW à 230 V CA 50/60 Hz (NEMA)
AC-23: 200 kW à 380/415 V CA 50/60 Hz
AC-23: 220 kW à 440 V CA 50/60 Hz
AC-23: 220 kW à 480 V CA 50/60 Hz (NEMA)
AC-23: 250 kW à 500/525 V CA 50/60 Hz
AC-23: 400 kW à 660/690 V CA 50/60 Hz
upstream connection Façade
downstream connection Façade
assigned department Ininterrompu
depth 130 mm
mounting bracket Platine
Rail
Network type CA
CC
order type Poignée rotative
Poles description 3P
Environment
degree of pollution 3
ip degree of protection IP40 se conformer à CEI 60529
product certificates KEMA-KEUR
CCC
operating ambient temperature -25…70 °C
standards CEI 60947-1
CEI 60947-3
shock resistance ik IK07 se conformer à EN 50102
storage room temperature -50…85 °C