31131 - Switch disconnector, Compact INS400 , 400 A, with red rotary handle and yellow front, 4 poles - Schneider Electric

Expected in 2-4 weeks
31131 - Switch disconnector, Compact INS400 , 400 A, with red rotary handle and yellow front, 4 poles - Schneider Electric - Switch disconnector, Compact INS400 , 400 A, with red rotary handle and yellow front, 4 poles - Schneider Electric - 0
31131 - Switch disconnector, Compact INS400 , 400 A, with red rotary handle and yellow front, 4 poles - Schneider Electric
562,21 € excl. VAT
685,90 € incl. VAT
Text About:
Switch disconnector, Compact INS400 , 400 A, with red rotary handle and yellow front, 4 poles - Schneider Electric
685,90 €
SPECIFICATIONS
Main
Range ComPact
Visible break No
Product Name ComPacT INS
[ui] rated insulation voltage 750 V AC 50/60 Hz
Complementary
[icm] rated short circuit making capacity 330 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz
50 kA switch-disconnector alone 690 V AC at 50/60 Hz
[ie] rated operational current AC-22A: 400 A AC 50/60 Hz 220/240 V
AC-22A: 400 A AC 50/60 Hz 380/415 V
AC-22A: 400 A AC 50/60 Hz 440/480 V
AC-22A: 400 A AC 50/60 Hz 480 V NEMA
AC-22A: 400 A AC 50/60 Hz 500/525 V
AC-22A: 400 A AC 50/60 Hz 660/690 V
AC-23A: 400 A AC 50/60 Hz 220/240 V
AC-23A: 400 A AC 50/60 Hz 380/415 V
AC-23A: 400 A AC 50/60 Hz 440/480 V
AC-23A: 400 A AC 50/60 Hz 480 V NEMA
AC-23A: 400 A AC 50/60 Hz 500/525 V
AC-23A: 400 A AC 50/60 Hz 660/690 V
DC-22A: 400 A DC 125 V 2 poles in series
DC-22A: 400 A DC 250 V 4 poles in series
DC-23A: 400 A DC 125 V 2 poles in series
DC-23A: 400 A DC 250 V 4 poles in series
[ue] rated operational voltage 250 V DC
690 V AC 50/60 Hz
[icw] rated short-time withstand current 11.5 kA during 3 s conforming to IEC 60947-3
20 kA during 1 s conforming to IEC 60947-3
4 kA during 30 s conforming to IEC 60947-3
4.9 kA during 20 s conforming to IEC 60947-3
[ith] conventional thermal current 400 A at 60 °C
Control type Red and yellow rotary handle
Handle colour Red
Product certifications CCC
KEMA-KEUR
Connection pitch 45 mm
Handle front plate colour 205 mm
Product or component type Switch disconnector
[uimp] rated impulse withstand voltage 8 kV
8 kV conforming to IEC 60947-3
Contact position indication Yes
width (w) 185 mm
network frequency 50/60 Hz
Ik degree of protection IK07 conforming to EN 50102
Mounting mode Fixed
maximum power AC-23: 110 kW at 220/240 V AC 50/60 Hz
AC-23: 110 kW at 230 V AC 50/60 Hz (NEMA)
AC-23: 200 kW at 380/415 V AC 50/60 Hz
AC-23: 220 kW at 440 V AC 50/60 Hz
AC-23: 220 kW at 480 V AC 50/60 Hz (NEMA)
AC-23: 250 kW at 500/525 V AC 50/60 Hz
AC-23: 400 kW at 660/690 V AC 50/60 Hz
Net weight 4.9 kg
Downside connection Front
Mounting support Plate
Rail
depth 130 mm
mechanical durability 10000 cycles
electrical durability AC-22A: 1500 cycles 440 V AC 50/60 Hz
AC-22A: 1500 cycles 500 V AC 50/60 Hz
AC-22A: 1500 cycles 690 V AC 50/60 Hz
AC-23A: 1500 cycles 440 V AC 50/60 Hz
AC-23A: 1500 cycles 500 V AC 50/60 Hz
AC-23A: 1500 cycles 690 V AC 50/60 Hz
DC-23A: 1000 cycles 250 V DC
Network type AC
DC
Pollution degree 3
Rated duty Uninterrupted
Suitability for isolation Yes
Poles description 4P
Upside connection Front
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
ambient air temperature for operation -25…70 °C
standards IEC 60947-1
IEC 60947-3