Main
calorimetric heat release nfpa 130 (astm e 1354)
28 MJ/kg
catalog page
Page 465 (C-1-2019)
flammability rating according to ul 94
V0
insulating material
PA
fire protection for rail vehicles (din en 45545-2) r22
HL 1 - HL 3
relative insulation material temperature index (elec., ul 746 b)
130 °C
fire protection for rail vehicles (din en 45545-2) r23
HL 1 - HL 3
gtin
4046356347303
number of rows
1
Product type
Ground terminal block
fire protection for rail vehicles (din en 45545-2) r24
HL 1 - HL 3
item number
3074143
fire protection for rail vehicles (din en 45545-2) r26
HL 1 - HL 3
nominal cross section
35 mm²
packing unit
50 pc
product key
BE1221
insulating material group
I
weight per piece (excluding packing)
79.4 g
weight per piece (including packing)
79.84 g
smoke gas toxicity nfpa 130 (smp 800c)
passed
specific optical density of smoke nfpa 130 (astm e 662)
passed
static insulating material application in cold
-60 °C
surface flammability nfpa 130 (astm e 162)
passed
temperature index of insulation material (din en 60216-1 (vde 0304-21))
130 °C
Complementary
maximum power dissipation for nominal condition
4.06 W
open side panel
No
height ns 35/7,5
62 mm
number of connections
2
rated surge voltage
8 kV
terminal block mounting
2.5 Nm ... 3 Nm (PE foot with mounting screw, M5)
conductor cross section, flexible [awg]
8 ... 2 (converted acc. to IEC)
Country of origin
CN
height ns 35/15
69.5 mm
length [l]
53.4 mm
conductor cross section, rigid [awg]
10 mm² ... 35 mm²
Handle front plate colour
2.441 "
tightening torque
3.2 ... 3.7 Nm
connection in acc. with standard
IEC 60947-7-2
cross section awg
8 ... 2 (converted acc. to IEC)
conductor cross section flexible, with ferrule without plastic sleeve
10 mm² ... 35 mm²
flexible conductor cross section (ferrule with plastic sleeve)
10 mm² ... 35 mm²
grounding foot
Yes
note
Please observe the current carrying capacity of the DIN rails.
number of connections per level
2
width (w)
16 mm
screw thread
M6
Colour
green-yellow
stripping length
16 mm
Minimum order quantity
1 pc
frequency
f1 = 5 Hz to f2 = 150 Hz
Environment
acceleration
5g
Ambient air temp for storage/transportation
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient air temperature for installation
-5 °C ... 70 °C
ambient temperature (actuation)
-5 °C ... 70 °C
china rohs
Environmentally friendly use period: unlimited = EFUP-e
Customs tariff number
85369010
degree of pollution
3
eclass-11.0
27141141
Specifications - Environmental Product Compliance:
No hazardous substances above threshold values
ambient air temperature for operation
-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
ETIM - 8
EC000901
overvoltage category
III
result
Test passed
permissible humidity (storage/transport)
30 % ... 70 %
unspsc 21.0
39121400
asd level
1.857 (m/s²)²/Hz
number of shocks per direction
3
pulse shape
Half-sine
shock duration
30 ms
specification
DIN EN 50155 (VDE 0115-200):2008-03
spectrum
Service life test category 1, class B, body mounted
test directions
X-, Y- and Z-axis (pos. and neg.)
test duration per axis
5 h