Additional Information
general
The max. current is determined by the diode. Installed: diode 1300 V 1 A, reverse voltage: 1300 V, maximum continuous current 0.5 A.
Main
calorimetric heat release nfpa 130 (astm e 1354)
27,5 MJ/kg
catalog page
Page 153 (C-1-2019)
flammability rating according to ul 94
V0
insulating material
PA
fire protection for rail vehicles (din en 45545-2) r22
HL 1 - HL 3
relative insulation material temperature index (elec., ul 746 b)
130 °C
fire protection for rail vehicles (din en 45545-2) r23
HL 1 - HL 3
gtin
4017918997205
number of rows
2
Product type
Component terminal block
fire protection for rail vehicles (din en 45545-2) r24
HL 1 - HL 3
item number
3046676
potentials
2
fire protection for rail vehicles (din en 45545-2) r26
HL 1 - HL 3
nominal cross section
2.5 mm²
packing unit
50 pc
product key
BE1172
insulating material group
I
weight per piece (excluding packing)
16.19 g
weight per piece (including packing)
16.19 g
smoke gas toxicity nfpa 130 (smp 800c)
passed
specific optical density of smoke nfpa 130 (astm e 662)
passed
static insulating material application in cold
-60 °C
surface flammability nfpa 130 (astm e 162)
passed
temperature index of insulation material (din en 60216-1 (vde 0304-21))
125 °C
Complementary
2 conductors with same cross section, flexible
0.14 mm² ... 1.5 mm²
end cover width
2.2 mm
maximum power dissipation for nominal condition
0.77 W
open side panel
Yes
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.14 mm² ... 1.5 mm²
height ns 35/7,5
65 mm
number of connections
4
rated surge voltage
6 kV
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
conductor cross section, flexible [awg]
26 ... 12 (converted acc. to IEC)
Country of origin
PL
height ns 35/15
72.5 mm
length [l]
69.9 mm
2 conductors with the same cross section, flexible, with twin ferrule with plastic sleeve
0.5 mm² ... 1.5 mm²
conductor cross section, rigid [awg]
0.14 mm² ... 4 mm²
Handle front plate colour
64.4 mm
tightening torque
0.5 ... 0.6 Nm
cross section awg
26 ... 12 (converted acc. to IEC)
conductor cross section flexible, with ferrule without plastic sleeve
0.14 mm² ... 2.5 mm²
flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
nominal voltage
500 V
internal cylindrical gage
A3
number of connections per level
2
width (w)
5.2 mm
screw thread
M3
Colour
gray
stripping length
9 mm
Minimum order quantity
50 pc
nominal current
0.5 A
frequency
f1 = 5 Hz to f2 = 150 Hz
Maximum load current
0.5 A
Environment
acceleration
5g
Ambient air temp for storage/transportation
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient air temperature for installation
-5 °C ... 70 °C
ambient temperature (actuation)
-5 °C ... 70 °C
china rohs
Environmentally Friendly Use Period = 50 years
Customs tariff number
85369010
degree of pollution
3
din rail/fixing support
NS 35
eclass-11.0
27141127
Specifications - Environmental Product Compliance:
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”
ambient air temperature for operation
-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
eclass-12.0
27141127
ETIM - 8
EC000903
overvoltage category
III
reach svhc
Lead 7439-92-1
result
Test passed
revolutions
135
rotation speed
10 rpm
short-time withstand current 2.5 mm²
0.3 kA
short-time withstand current 4 mm²
0.48 kA
test force setpoint
1 N
test voltage setpoint
1.89 kV
permissible humidity (storage/transport)
30 % ... 70 %
unspsc 21.0
39121400
asd level
0.02g²/Hz
time of exposure
30 s
number of shocks per direction
3
pulse shape
Half-sine
shock duration
30 ms
specification
DIN EN 50155 (VDE 0115-200):2008-03
spectrum
Service life test category 1, class B, body mounted
test directions
X-, Y- and Z-axis (pos. and neg.)
test duration per axis
5 h