3044102 - UT 4 - Phoenix Contact

Expected in 2-4 weeks
3044102 - UT 4 - Phoenix Contact - UT 4 - Phoenix Contact - 0
3044102 - UT 4 - Phoenix Contact - UT 4 - Phoenix Contact - 1
3044102 - UT 4 - Phoenix Contact - UT 4 - Phoenix Contact - 2
3044102 - UT 4 - Phoenix Contact
0,29 € excl. VAT
0,35 € incl. VAT
Text About:
UT 4 - Phoenix Contact
0,35 €
SPECIFICATIONS
Additional Information
- at bridging between non-adjacent terminal blocks 352 V
bridge data 27 A / 4 mm²
connection capacity awg 26 ... 12
- at cut-to-length bridging 275 V
2 conductors with same cross section, stranded 0.14 mm² ... 1.5 mm²
connection capacity flexible 0.14 mm² ... 4 mm²
2 conductors with the same cross-section awg flexible 26 ... 16
connection capacity rigid 0.14 mm² ... 6 mm²
2 conductors with the same cross-section awg rigid 26 ... 16
identification  II 2 GD  Ex eb IIC Gb
ex temperature increase 40 K (33.3 A / 4 mm²)
output (Permanent)
for bridging with bridge 690 V
rated cross section awg 12
torque range 0.6 Nm ... 0.8 Nm
Main
calorimetric heat release nfpa 130 (astm e 1354) 27,5 MJ/kg
catalog page Page 159 (C-1-2019)
flammability rating according to ul 94 V0
insulating material PA
fire protection for rail vehicles (din en 45545-2) r22 HL 1 - HL 3
product family UT
relative insulation material temperature index (elec., ul 746 b) 130 °C
fire protection for rail vehicles (din en 45545-2) r23 HL 1 - HL 3
gtin 4017918960391
number of rows 1
Product type Feed-through terminal block
fire protection for rail vehicles (din en 45545-2) r24 HL 1 - HL 3
item number 3044102
potentials 1
Rated voltage 690 V
fire protection for rail vehicles (din en 45545-2) r26 HL 1 - HL 3
nominal cross section 4 mm²
packing unit 50 pc
product key BE1111
insulating material group I
weight per piece (excluding packing) 8.9 g
weight per piece (including packing) 9.494 g
smoke gas toxicity nfpa 130 (smp 800c) passed
specific optical density of smoke nfpa 130 (astm e 662) passed
static insulating material application in cold -60 °C
surface flammability nfpa 130 (astm e 162) passed
temperature index of insulation material (din en 60216-1 (vde 0304-21)) 125 °C
Complementary
2 conductors with same cross section, flexible 0.14 mm² ... 1.5 mm²
end cover width 2.2 mm
maximum power dissipation for nominal condition 1.02 W
open side panel Yes
[in] rated current 30 A
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.14 mm² ... 1.5 mm²
height ns 35/7,5 47.5 mm
number of connections 2
rated surge voltage 8 kV
2 conductors with same cross section, solid 0.14 mm² ... 1.5 mm²
conductor cross section, flexible [awg] 26 ... 10 (converted acc. to IEC)
Country of origin DE
height ns 35/15 55 mm
length [l] 47.7 mm
2 conductors with the same cross section, flexible, with twin ferrule with plastic sleeve 0.5 mm² ... 2.5 mm²
conductor cross section, rigid [awg] 0.14 mm² ... 6 mm²
Handle front plate colour 46.9 mm
tightening torque 0.6 ... 0.8 Nm
connection in acc. with standard IEC 60947-7-1
cross section awg 26 ... 10 (converted acc. to IEC)
Rated insulation voltage 630 V
conductor cross section flexible, with ferrule without plastic sleeve 0.14 mm² ... 4 mm²
flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 4 mm²
nominal voltage 1000 V
internal cylindrical gage A4
note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
number of connections per level 2
width (w) 6.2 mm
screw thread M3
Colour gray
stripping length 9 mm
Minimum order quantity 1 pc
nominal current 32 A (with 4 mm² conductor cross section)
contact resistance 0.26 mΩ
frequency f1 = 5 Hz to f2 = 150 Hz
Maximum load current 38 A
Environment
acceleration 5g
Ambient air temp for storage/transportation -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient air temperature for installation -5 °C ... 70 °C
ambient temperature (actuation) -5 °C ... 70 °C
china rohs Environmentally Friendly Use Period = 50 years
Customs tariff number 85369010
degree of pollution 3
din rail/fixing support NS 35
eclass-11.0 27141120
requirement temperature-rise test Increase in temperature ≤ 45 K
Specifications - Environmental Product Compliance: For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”
ambient air temperature for operation -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
ETIM - 8 EC000897
overvoltage category III
reach svhc Lead 7439-92-1
result Test passed
revolutions 135
operating temperature range -60 °C ... 110 °C
rotation speed 10 rpm
short-time withstand current 4 mm² 0.48 kA
short-time withstand current 6 mm² 0.72 kA
test force setpoint 1 N
test voltage setpoint 2.2 kV
permissible humidity (storage/transport) 30 % ... 70 %
unspsc 21.0 39121400
asd level 1.857 (m/s²)²/Hz
time of exposure 30 s
number of shocks per direction 3
pulse shape Half-sine
shock duration 30 ms
specification DIN EN 50155 (VDE 0115-200):2008-03
spectrum Service life test category 1, class B, body mounted
test directions X-, Y- and Z-axis (pos. and neg.)
test duration per axis 5 h