Main
calorimetric heat release nfpa 130 (astm e 1354)
28 MJ/kg
catalog page
Page 322 (C-1-2019)
number of positions
6
flammability rating according to ul 94
V0
insulating material
PA
fire protection for rail vehicles (din en 45545-2) r22
HL 1 - HL 3
relative insulation material temperature index (elec., ul 746 b)
130 °C
fire protection for rail vehicles (din en 45545-2) r23
HL 1 - HL 3
gtin
4017918833138
Product type
Terminal plug
fire protection for rail vehicles (din en 45545-2) r24
HL 1 - HL 3
item number
3040452
potentials
6
fire protection for rail vehicles (din en 45545-2) r26
HL 1 - HL 3
nominal cross section
2.5 mm²
packing unit
25 pc
product key
BE2144
insulating material group
I
weight per piece (excluding packing)
29.708 g
weight per piece (including packing)
29.708 g
smoke gas toxicity nfpa 130 (smp 800c)
passed
specific optical density of smoke nfpa 130 (astm e 662)
passed
static insulating material application in cold
-60 °C
surface flammability nfpa 130 (astm e 162)
passed
temperature index of insulation material (din en 60216-1 (vde 0304-21))
130 °C
Complementary
rated surge voltage
6 kV
conductor cross section, flexible [awg]
28 ... 14 (converted acc. to IEC)
Country of origin
PL
length [l]
32.7 mm
2 conductors with the same cross section, flexible, with twin ferrule with plastic sleeve
0.5 mm²
conductor cross section, rigid [awg]
0.08 mm² ... 4 mm²
Handle front plate colour
39 mm
connection in acc. with standard
IEC 61984
Pitch
5.2 mm
cross section awg
28 ... 12 (converted acc. to IEC)
conductor cross section flexible, with ferrule without plastic sleeve
0.14 mm² ... 2.5 mm²
flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
nominal voltage
500 V
internal cylindrical gage
A3
width (w)
31.2 mm
Colour
gray
stripping length
8 mm ... 10 mm
Minimum order quantity
1 pc
nominal current
24 A
Maximum load current
24 A (with 4 mm² conductor cross section)
Environment
Ambient air temp for storage/transportation
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient air temperature for installation
-5 °C ... 70 °C
ambient temperature (actuation)
-5 °C ... 70 °C
china rohs
Environmentally friendly use period: unlimited = EFUP-e
Customs tariff number
85366990
degree of pollution
3
eclass-11.0
27141151
Specifications - Environmental Product Compliance:
No hazardous substances above threshold values
ambient air temperature for operation
-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
eclass-12.0
27141151
ETIM - 8
EC002021
overvoltage category
III
eclass-13.0
27250306
permissible humidity (storage/transport)
30 % ... 70 %
unspsc 21.0
39121400