SPECIFICATIONS
Main
calorimetric heat release nfpa 130 (astm e 1354) 28 MJ/kg
catalog page Page 243 (C-1-2019)
flammability rating according to ul 94 V0
insulating material PA
fire protection for rail vehicles (din en 45545-2) r22 HL 1 - HL 3
relative insulation material temperature index (elec., ul 746 b) 130 °C
fire protection for rail vehicles (din en 45545-2) r23 HL 1 - HL 3
gtin 4046356100762
number of rows 1
Product type Multi-conductor terminal block
fire protection for rail vehicles (din en 45545-2) r24 HL 1 - HL 3
item number 3035288
potentials 1
fire protection for rail vehicles (din en 45545-2) r26 HL 1 - HL 3
nominal cross section 10 mm²
packing unit 25 pc
product key BE2112
insulating material group I
weight per piece (excluding packing) 35.844 g
weight per piece (including packing) 36.014 g
smoke gas toxicity nfpa 130 (smp 800c) passed
specific optical density of smoke nfpa 130 (astm e 662) passed
static insulating material application in cold -60 °C
surface flammability nfpa 130 (astm e 162) passed
temperature index of insulation material (din en 60216-1 (vde 0304-21)) 130 °C
Complementary
end cover width 2.2 mm
maximum power dissipation for nominal condition 1.82 W
open side panel Yes
height ns 35/7,5 50.3 mm
number of connections 3
rated surge voltage 8 kV
conductor cross section, flexible [awg] 24 ... 8 (converted acc. to IEC)
Country of origin PL
height ns 35/15 57.8 mm
length [l] 95.4 mm
2 conductors with the same cross section, flexible, with twin ferrule with plastic sleeve 1.5 mm² ... 2.5 mm²
conductor cross section, rigid [awg] 0.2 mm² ... 16 mm²
connection in acc. with standard IEC 60947-7-1
cross section awg 24 ... 6 (converted acc. to IEC)
conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 10 mm²
flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 10 mm²
nominal voltage 1000 V
internal cylindrical gage A6
number of connections per level 3
width (w) 10.2 mm
Colour gray
stripping length 18 mm
Minimum order quantity 1 pc
nominal current 57 A (with 16 mm² conductor cross section)
frequency f1 = 5 Hz to f2 = 250 Hz
Maximum load current 57 A
Environment
acceleration 30g
Ambient air temp for storage/transportation -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient air temperature for installation -5 °C ... 70 °C
ambient temperature (actuation) -5 °C ... 70 °C
china rohs Environmentally friendly use period: unlimited = EFUP-e
Customs tariff number 85369010
degree of pollution 3
din rail/fixing support NS 35
eclass-11.0 27141120
requirement temperature-rise test Increase in temperature ≤ 45 K
Specifications - Environmental Product Compliance: No hazardous substances above threshold values
ambient air temperature for operation -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
ETIM - 8 EC000897
overvoltage category III
result Test passed
revolutions 135
rotation speed 10 rpm
short-time withstand current 10 mm² 1.2 kA
test force setpoint 5 N
test voltage setpoint 2.2 kV
permissible humidity (storage/transport) 30 % ... 70 %
unspsc 21.0 39121400
asd level 6.12 (m/s²)²/Hz
time of exposure 30 s
number of shocks per direction 3
pulse shape Half-sine
shock duration 18 ms
specification DIN EN 50155 (VDE 0115-200):2008-03
spectrum Service life test category 2, bogie-mounted
temperature cycles 192
test directions X-, Y- and Z-axis (pos. and neg.)
test duration per axis 5 h