Additional Information
Connecting capacity Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
curve B
Data sheet, technical information 9AKK107492A6187
Eclass V11.0 : 27142207
Package level 1 depth / length 80 mm
Operating characteristic Instantaneous
Product net depth / length 0.069
m
Rohs status Following EU Directive 2011/65/EU
Resistance to vibrations acc 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Weee category 5. Small Equipment (No External Dimension More Than 50 cm)
Main
Terminal type Screw Terminals
Number of protected poles 1
Mounting type on DIN rail EN 60715 (35mm) by means of mounting clip
degree of protection Terminals IP20
Housing IP40
sensitivity to earth leakage 300 mA
Complementary
Accessories available Yes
Accessory type Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator type Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Ambient air temperature Operation -25...55 °C
Ccc certificate 9AKK107492A6067
Cn8 85363030
Declaration of conformity - ce 9AKK106713A5588
Package level 1 gross weight 225 g
Product net weight 0.200
kg
[in] rated current 25 A
Package level 1 height 106 mm
Product net width 0.035
m
[ics] rated service breaking capacity 7.5 kA
Cb certificate 9AKK107492A6060
Country of origin Italy (IT)
Environmental conditions 28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Package level 1 units box 1 piece
Package level 1 width 40 mm
tightening torque 2.8 N·m
Package level 2 depth / length 80 mm
Package level 2 ean 8012542598114
Contact position indication Red ON / Green OFF
Environmental information 2CSC422002K2701
Package level 2 gross weight 1125 g
Package level 2 height 106 mm
Package level 2 units box 5 piece
Dnv gl certificate 9AKK107680A3457


9AKK107680A3456
Instructions and manuals 9AKK107492A6006
mechanical endurance 20000 cycle
Package level 2 width 200 mm
Position of neutral terminals Right
fault indication Blue flag on toggle
Minimum order quantity 1 piece
Number of modular spacings per din rail 2
Input voltage type AC
Power supply connection Arbitrary
wire stripping length 12 mm
Object classification code F
Rated conditional short-circuit current (inc) 10 kA
frequency 50/60 Hz
Network type AC type
Package level 1 ean 8012542644316
Pollution degree 2
Product net height 0.085
m
Rated short-circuit capacity 6 kA
mounting position Any
Rated frequency (f) 50 … 60 Hz
Primary rated impulse withstand voltage 4 kV
Rated insulation voltage (ui) 500 V
Rated voltage (ur) 230 V
Power loss 5.5 W
Rated residual breaking capacity (iδm) EN 61009-1 6000 A
IEC 61009-1 6000 A
Rated operational voltage 230 / 240 V AC
Reach declaration 9AKK108467A9482
Poles description 2
Resistance to shock acc 25g 2 shocks 13 ms
Test voltage (ut) 110 ... 264 V
Öve certificate 9AKK107492A6085
Rated ultimate short-circuit breaking capacity (icu) 10 kA
Environment
Built-in depth (t2) 69 mm
Customs tariff number 85363030
EAC certificate 9AKK107492A6071


9AKK107991A7755
Electrical endurance 10000 cycle
Energy limiting class 3
Eplan catalog tree Electrical engineering / Protection devices / Ground fault current circuit breaker
Housing type Insulation group I - II, RAL 7035
Release type B
Cable size 25 mm²
Eplan macro 9AKK107680A0597
ETIM - 8 EC000905 - Earth leakage circuit breaker
Gost certificate 9AKK107992A1640
overvoltage category III
Rmrs certificate 9AKK107680A3454


9AKK107680A3455
standards IEC/EN 61009-1, IEC/EN 61009-2-1
Etim 7 EC000905 - Earth leakage circuit breaker
Width in number of modular spacings 2
Maximum surge current 0 kA
Reference ambient air temperature 30 °C
Leakage current type AC
Weee b2c / b2b Business To Consumer
Rohs information 9AKK106713A5588
Screw terminal type Failsafe Bi-directional Cylinder-lift Terminal
dielectric test voltage 2 kV