Additional Information
Connecting capacity
Busbar 10 mm²
Rigid 35 ... 35 mm²
Flexible 35 ... 35 mm²
Data sheet, technical information
9AKK107991A8329
Eclass
V11.0 : 27142201
Package level 1 depth / length
94 mm
Operating characteristic
Instantaneous
Product net depth / length
0.069
m
Rohs status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Resistance to vibrations acc
0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Weee category
5. Small Equipment (No External Dimension More Than 50 cm)
Main
Mounting type
DIN rail
degree of protection
IP2X
sensitivity to earth leakage
300 mA
Complementary
Accessories available
Yes
Ambient air temperature
Operation -25...55 °C
Cn8
85363030
Declaration of conformity - ce
9AKK106713A5602
Package level 1 gross weight
0.415 kg
Product net weight
0.380
kg
[in] rated current
80 A
Package level 1 height
82 mm
Product net width
0.070
m
[ics] rated service breaking capacity
1 kA
Country of origin
Italy (IT)
Package level 1 units
box 1 piece
Package level 1 width
80 mm
Package level 2 depth / length
245 mm
Package level 2 ean
8012542917014
Environmental information
Refer to RoHS
Package level 2 gross weight
1215 g
Package level 2 height
80 mm
Idea granular category code (igcc)
4875 >> Residual current circuit breaker (RCCB)
Package level 2 units
box 3 piece
Instructions and manuals
9AKK107991A6127
Package level 2 width
90 mm
Maximum operating voltage ul/csa
480Y / 277 V AC
Position of neutral terminals
Right
Minimum order quantity
1 piece
Options provided
None
Power supply connection
Arbitrary
Object classification code
F
Rated conditional short-circuit current (inc)
10 kA
Network type
AC type
Package level 1 ean
8012542917007
Rated cross-section
4 - Multi-Wired 0...35 mm²
1 - Solid-Core 35...35 mm²
Pollution degree
2
Product net height
0.085
m
Rated frequency (f)
50 … 60 Hz
Rated impulse withstand voltage (uimp)
4 kV
Rated insulation voltage (ui)
500 V
Rated voltage (ur)
230/400 V
Power loss
at Rated Operating Conditions per Pole 5.3 W
Rated operational voltage
230 / 400 V AC
Reach declaration
9AKK108467A9482
Poles description
4
Resistance to shock acc
25g 2 shocks 13 ms
Short-circuit current rating (sccr)
300 mA
Environment
Built-in depth (t2)
69 mm
Customs tariff number
85363030
Electrical endurance
10000 cycle
Eplan catalog tree
Electrical engineering / Protection devices / Ground fault current circuit breaker
Environmental product declaration - epd
9AKK108467A3700
ETIM - 8
EC000003 - Residual current circuit breaker (RCCB)
standards
IEC/EN 61008
UL 1053
Etim 7
EC000003 - Residual current circuit breaker (RCCB)
Width in number of modular spacings
4
Eplan function definition
Ground fault current circuit-breaker / Ground fault current circuit breakers, 8 connection points / Ground fault current circuit breaker, four-pole 1_2_3_4_5_6_N_N.
Maximum surge current
0.25 kA
Leakage current type
AC
Weee b2c / b2b
Business To Consumer
Rohs information
9AKK106713A5602
Unspsc
39121601