Additional Information
Connecting capacity
Busbar 10 / 10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
curve
Z
Data sheet, technical information
9AKK107046A0423
Eclass
V11.0 : 27141901
Package level 1 depth / length
183 mm
Product net depth / length
69
mm
Rohs status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Resistance to vibrations acc
5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
Weee category
5. Small Equipment (No External Dimension More Than 50 cm)
Main
Terminal type
Screw Terminals
Number of protected poles
2
i²t at switch-on
9AKK107992A5104
degree of protection
IP20
Enclosure with Cover IP40
Complementary
Accessories available
Yes
Actuator marking
I / O
Ambient air temperature
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Cn8
8536 20 10
Declaration of conformity - ce
2CDK403001D0607
Package level 1 gross weight
1.3 kg
Product net weight
0.25
kg
[in] rated current
10 A
Actuator material
Insulation Group II, Black, Sealable
Package level 1 height
80 mm
Product net width
35
mm
[ics] rated service breaking capacity
(230 V AC) 10 kA
Country of origin
Germany (DE)
Environmental conditions
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Package level 1 units
carton 5 piece
Connecting capacity ul/csa
Busbar 14-8 AWG
Conductor 14-4 AWG
Package level 1 width
92 mm
tightening torque
2.8 N·m
dimension
2CDC022007F0010
Package level 2 depth / length
400 mm
Package level 2 ean
4016779977562
Contact position indication
Red ON / Green OFF
Environmental information
2CDK400030D0201
Package level 2 gross weight
16 kg
Package level 2 height
210 mm
Idea granular category code (igcc)
4897 >> Miniature circuit breakers
Operational voltage
Maximum (Incl. Tolerance) 125 V DC
Maximum (Incl. Tolerance) 440 V AC
Minimum 12 V AC
Minimum 12 V DC
Package level 2 units
carton 60 piece
Instructions and manuals
2CDS207104P0002
mechanical endurance
20000 cycle
Package level 2 width
275 mm
Maximum operating voltage ul/csa
125 V DC
480Y / 277 V AC
Minimum order quantity
1 piece
Input voltage type
AC/DC
Power supply connection
Arbitrary
Object classification code
F
Rated conditional short-circuit current (inc)
(230 V) 15 kA
(400 V) 25 kA
Package level 1 ean
4016779603591
Housing material
Insulation Group II, RAL 7035
Offered with extended lifetime
Product Durability - Achieved
Pollution degree
3
Product net height
88
mm
Rated short-circuit capacity
(AC) 10 kA
(DC) 10 kA
(230 V AC) 10 kA
(400 V AC) 10 kA
mounting position
any
Rated frequency (f)
50 / 60 Hz
Rated impulse withstand voltage (uimp)
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
Mounting on din rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui)
acc. to IEC/EN 60664-1 440 V
Power loss
5.4 W
at Rated Operating Conditions per Pole 2.7 W
Rated operational voltage
acc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 440 V AC
Reach declaration
9AKK107492A1906
Poles description
2
Recommended screw driver
Pozidriv 2
Resistance to shock acc
25g / 2 shocks / 13 ms
Tightening torque ul/csa
18 in·lb
Sustainable material content
0 %
Rated ultimate short-circuit breaking capacity (icu)
(230 V AC) 25 kA
(400 V AC) 15 kA
(440 V AC) 15 kA
Environment
Built-in depth (t2)
69 mm
Customs tariff number
85362010
Energy limiting class
3
Eplan catalog tree
Electrical engineering / Protection devices / General
Certification agency
CSA
EN
IEC
UL
Environmental product declaration - epd
9AKK108467A7833
Eplan graphical macro
9AKK106713A8115
Eplan macro
9AKK106713A8105
ETIM - 8
EC000042 - Miniature circuit breaker (MCB)
overvoltage category
III
standards
CSA 22.2 No. 235
IEC/EN 60947-2
UL 1077
Circular design principles recyclability rate
Design for Closing Resource Loops - Standard EN45555 - 90 %
Declaration of conformity - ukca
9AKK108467A5053
Etim 7
EC000042 - Miniature circuit breaker (MCB)
Pole net weight
0.125 kg
Width in number of modular spacings
2
Eplan function definition
Circuit breaker / Double circuit-breaker / Double circuit breaker 1_2_3_4
Reference ambient air temperature
30 °C
Weee b2c / b2b
Business To Business
Offered with takeback services
Take Back for Recycling - Achieved
Rohs information
2CDK400003K0203
Screw terminal type
Failsafe Bi-directional Cylinder-lift Terminal
Unspsc
39121603
Installation size
acc. to DIN 43880 1
dielectric test voltage
50/60 Hz, 1 min: 2 kV
Interrupting rating acc
(125 V DC) 10 kA
(277 V AC) 6 kA
(480Y / 277 V AC) 6 kA