29472 - Remote control source changeover, Transferpact, ACP plate and UA controller, 220 VAC to 240 VAC 50/6 - Schneider Electric

Expected in 2-4 weeks
29472 - Remote control source changeover, Transferpact, ACP plate and UA controller, 220 VAC to 240 VAC 50/6 - Schneider Electric - Remote control source changeover, Transferpact, ACP plate and UA controller, 220 VAC to 240 VAC 50/6 - Schneider Electric - 0
29472 - Remote control source changeover, Transferpact, ACP plate and UA controller, 220 VAC to 240 VAC 50/6 - Schneider Electric
1 126,10 € excl. VAT
1 373,84 € incl. VAT
Text About:
Remote control source changeover, Transferpact, ACP plate and UA controller, 220 VAC to 240 VAC 50/6 - Schneider Electric
1 373,84 €
SPECIFICATIONS
Main
Accessory category Interlocking accessory
Device short name ACP + UA
Complementary
product compatibility Compact NS630b...1600
Compact NSX100...250
Compact NSX400...630
[ie] rated operational current AC-12: 4 A AC 440 V
AC-12: 5 A AC 380/415 V
AC-12: 8 A AC 110 V
AC-12: 8 A AC 220/240 V
AC-12: 8 A AC 24 V
AC-12: 8 A AC 48 V
AC-13: 6 A AC 110 V
AC-13: 6 A AC 220/240 V
AC-13: 7 A AC 24 V
AC-13: 7 A AC 48 V
AC-14: 4 A AC 110 V
AC-14: 4 A AC 220/240 V
AC-14: 5 A AC 24 V
AC-14: 5 A AC 48 V
AC-15: 3 A AC 220/240 V
AC-15: 4 A AC 110 V
AC-15: 5 A AC 24 V
AC-15: 5 A AC 48 V
DC-12: 0.4 A DC 250 V
DC-12: 0.6 A DC 110 V
DC-12: 2 A DC 48 V
DC-12: 8 A DC 24 V
DC-13: 2 A 24 V
Interlocked device MasterPact NT
NSX400...630
MasterPact NW
NSX100...250
Compact NS100...630
Compact NS630b...1600
range compatibility ComPact (ComPact NS) circuit breaker
ComPact (ComPact NSX) circuit breaker
Masterpact (MasterPact NT) circuit breaker
Masterpact (MasterPact NW) circuit breaker
[ith] conventional thermal current 8 A
Complementary function Voluntary transfer to replacement source (e.g. energy management commands)
Forced normal source if replacement source not operational during peak-tariff
Selection of type of normal source (single-phase or three-phase)
Setting of maximum startup time for the replacement source
Additional contact: transfer to replacement source only if contact is closed
Product or component type Interface and control unit
[us] rated supply voltage 220...240 V AC at 50/60 Hz
Output type Contacts customer: indication of operation in automatic or stop mode
Selection modes Circuit breaker on R
Circuit breaker on N
Ik degree of protection Front: IK07 conforming to EN 50102
input type Contacts customer voluntary order to transfer to source R
Local signalling On
Off
Fault trip
Test function By pressing the test button on the front of the controller
Operating mode Automatic operation
Forced operation on normal source
Stop (both normal and replacement source off)
Forced operation on replacement source
Environment
ip degree of protection IP20 connectors: conforming to EN 60529
IP40 front: conforming to EN 60529
IP30 side: conforming to EN 60529
Range of product NSX100...250
Compact NS100...630
MasterPact NW
MasterPact NT
NSX400...630
Compact NS630b...1600
standards IEC 947-5-1