1SFL637001R7022 - CONTACTOR AF750-30-22 100-250V - ABB

Expected in 2-4 weeks
1SFL637001R7022 - CONTACTOR AF750-30-22 100-250V - ABB - CONTACTOR AF750-30-22 100-250V - ABB - 0
1SFL637001R7022 - CONTACTOR AF750-30-22 100-250V - ABB
2 248,48 € excl. VAT
2 743,15 € incl. VAT
Text About:
CONTACTOR AF750-30-22 100-250V - ABB
2 743,15 €
SPECIFICATIONS
Additional Information
Bv certificate BV_13409-C0BV
Csa certificate 306712-1
Data sheet, technical information 1SBC100192C0206
Eclass V11.0 : 27371003
Package level 1 depth / length 375 mm
Product net depth / length 242
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Main
Terminal type Main Circuit: Bars
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... +70 °C
Declaration of conformity - ce 2CMT2019-005796
Package level 1 gross weight 15 kg
Product net weight 13.6
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 310 mm
Product net width 210
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Cb certificate SE-82863
Package level 1 units box 1 piece
Package level 1 width 280 mm
Connecting capacity main circuit Bar 52 mm²
Rigid Al-Cable 3x185 mm²
Rigid Cu-Cable 300 mm²
dimension 53540919-60
Cqc certificate CQC2007010304256684


CQC2012010304540080
Environmental information 1SFC101005D0201


1SAC200044H0006
Horsepower rating ul/csa (200 V AC) Three Phase 250 hp
(208 V AC) Three Phase 250 hp
(220 ... 240 V AC) Three Phase 300 hp
(440 ... 480 V AC) Three Phase 600 hp
(550 ... 600 V AC) Three Phase 700 hp
Idea granular category code (igcc) 4758 >> Iec Contactors
Dnv gl certificate TAE00001W1
Instructions and manuals 1SFC380023-en
Number of auxiliary contacts no 2
Horsepower rating nema (230 V AC) Three Phase 300 Hp
(460 V AC) Three Phase 600 Hp
(575 V AC) Three Phase 600 Hp
Maximum operating altitude permissible Without Derating 3000 m
Maximum operating voltage ul/csa Main Circuit 1000 V
Lovag certificate FI105
Gl certificate GL_42988-02HH
Minimum order quantity 1 piece
Maximum mechanical switching frequency 300 cycles per hour
mechanical durability 3 million
Number of main contacts no 3
Object classification code Q
Package level 1 ean 7320500222072
Nema size 7
Product net height 283
mm
Rated control circuit voltage (uc) 50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Rated frequency (f) Main Circuit 50 / 60 Hz
Prs certificate TE_2092_880423_16
Rated impulse withstand voltage (uimp) Main Circuit 8 kV
Rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (1000 V) 40 °C 1000 A
(1000 V) 55 °C 875 A
(1000 V) 70 °C 720 A
(690 V) 40 °C 1050 A
(690 V) 55 °C 875 A
(690 V) 70 °C 720 A
Rated operational current ac-3 (ie) (415 V) 55 °C 750 A
(440 V) 55 °C 750 A
(500 V) 55 °C 750 A
(690 V) 55 °C 650 A
(1000 V) 55 °C 300 A
(380 / 400 V) 55 °C 750 A
(220 / 230 / 240 V) 55 °C 750
Operate time Between Coil De-energization and NC Contact Closing 50 ... 70 ms
Between Coil De-energization and NO Contact Opening 53 ... 73 ms
Between Coil Energization and NC Contact Opening 45 ... 115 ms
Between Coil Energization and NO Contact Closing 50 ... 120 ms
Rated making capacity ac-3 10 x Ie AC-3
Rated operational power ac-3 (pe) (415 V) 425 kW
(440 V) 450 kW
(500 V) 520 kW
(690 V) 600 kW
(1000 V) 400 kW
(380 / 400 V) 400 kW
(220 / 230 / 240 V) 220 kW
Rated operational current dc-1 (ie) (110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(850 V) 3 Poles in Series, 40 °C 1050 A
Rated operational voltage Main Circuit 1000 V
Reach declaration 2CMT2021-006202
Rated operational current dc-3 (ie) (110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(850 V) 3 Poles in Series, 40 °C 1050 A
Resistance to shock acc Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Rated operational current dc-5 (ie) (110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(850 V) 3 Poles in Series, 40 °C 1050 A
Ul certificate UL_20111101-E36588
Ul listing card UL_E36588
Environment
Ccs certificate GB14T00030
Coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage DC 5 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Customs tariff number 85364900
EAC certificate 9AKK107046A8618
Rina certificate ELE060313XG_002
Declaration of conformity - ccc 2020980304001301


2020980304001045
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Rmrs certificate 9AKK107045A6978
Short-circuit protective devices gG Type Fuses 1000 A
Declaration of conformity - ukca 2CMT2020-006118
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (1000 V AC) 900 A
(600 V AC) 900 A
Dnv certificate DNV_E-10966
Lr certificate 16-20064
E-number (finland) 3707173
Number of auxiliary contacts nc 2
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-1) 300 cycles per hour
(AC-2 / AC-4) 60 cycles per hour
(AC-3) 300 cycles per hour
Unspsc 39121529
Rated breaking capacity ac-3 8 x Ie AC-3