All categories
Compare Cart

1SFL587102R1411 - Contactor AF305-40-11-14 250-500V - ABB

Expected in 2-4 weeks
1SFL587102R1411 - Contactor AF305-40-11-14 250-500V - ABB - Contactor AF305-40-11-14 250-500V - ABB - 0
1SFL587102R1411 - Contactor AF305-40-11-14 250-500V - ABB
1 115,41 € excl. VAT
1 360,80 € incl. VAT
Text About:
Contactor AF305-40-11-14 250-500V - ABB
1 360,80 €
SPECIFICATIONS
Additional Information
Bv certificate BV_36353_A0BV
Data sheet, technical information 1SBC100192C0206
E-number (sweden) 3210345
Eclass V11.0 : 27371003
Package level 1 depth / length 262 mm
Product net depth / length 180
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Main
Terminal type Main Circuit: Bars
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... +70 °C
Declaration of conformity - ce 2CMT2015-005439
Package level 1 gross weight 6.4 kg
Product net weight 5.7
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 212 mm
Product net width 184
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A
Cb certificate SE-89316
Package level 1 units box 1 piece
Package level 1 width 212 mm
Connecting capacity main circuit Flexible 1 x 16 ... 240 mm²
Rigid Al-Cable 1 x 185 ... 240 mm²
Rigid Cu-Cable 1 x 6 ... 300 mm²
dimension 1SFB535001G1123
Cqc certificate CQC2014010304676670
Idea granular category code (igcc) 4758 >> Iec Contactors
Dnv gl certificate DNV_E-14043
Instructions and manuals 1SFC101066M0201
Number of auxiliary contacts no 1
Maximum operating altitude permissible Without Derating 3000 m
Maximum operating voltage ul/csa Main Circuit 1000 V
Minimum order quantity 1 piece
Maximum mechanical switching frequency 300 cycles per hour
mechanical durability 5 million
Number of main contacts no 4
Object classification code Q
Package level 1 ean 7320500504970
Product net height 225.4
mm
Rated control circuit voltage (uc) 50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated frequency (f) Main Circuit 60 Hz
Prs certificate TE_2092_880423_16
Rated impulse withstand voltage (uimp) Main Circuit 8 kV
Rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (1000 V) 40 °C 375 A
(1000 V) 60 °C 325 A
(1000 V) 70 °C 260 A
(690 V) 40 °C 500 A
(690 V) 60 °C 400 A
(690 V) 70 °C 325 A
Rated operational current ac-3 (ie) (415 V) 55 °C 305 A
(440 V) 55 °C 305 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305
Operate time Between Coil De-energization and NO Contact Opening 45 ... 80 ms
Between Coil Energization and NO Contact Closing 30 ... 60 ms
Rated making capacity ac-3 10 x Ie AC-3
Rated operational power ac-3 (pe) (415 V) 160 kW
(440 V) 160 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
Rated operational voltage Main Circuit 1000 V
Reach declaration 2CMT2021-006202
Ul certificate 20140910-E73397
Environment
Coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 20.4 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 20.4 V·A
Holding at Max. Rated Control Circuit Voltage DC 4.7 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 550 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 650 W
Coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Customs tariff number 85364900
EAC certificate 9AKK107046A8618
Rina certificate ELE060313XG_002
Declaration of conformity - ccc 2020980304001305
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Rmrs certificate 9AKK107045A6978
Short-circuit protective devices gG Type Fuses 630 A
Declaration of conformity - ukca 2CMT2020-006118
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (600 V AC) 350 A
Lr certificate LR_14_70011(E1)
E-number (finland) 3707241
Number of auxiliary contacts nc 1
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-1) 300 cycles per hour
Unspsc 39121529
E-number (norway) 3210345
Rated breaking capacity ac-3 8 x Ie AC-3
Recently viewed
1 115,41 € excl. VAT
1 360,80 € incl. VAT
Expected in 2-4 weeks