All categories
Compare Cart

1SFL577001R7122 - CONTACTOR AF400-30-22 250-500V - ABB

Expected in 2-4 weeks
1SFL577001R7122 - CONTACTOR AF400-30-22 250-500V - ABB - CONTACTOR AF400-30-22 250-500V - ABB - 0
1SFL577001R7122 - CONTACTOR AF400-30-22 250-500V - ABB
892,66 € excl. VAT
1 089,04 € incl. VAT
Text About:
CONTACTOR AF400-30-22 250-500V - ABB
1 089,04 €
SPECIFICATIONS
Additional Information
Bv certificate BV_13409-C0BV
Data sheet, technical information 1SBC100192C0206
Eclass V11.0 : 27371003
Package level 1 depth / length 375 mm
Product net depth / length 216
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Main
Terminal type Main Circuit: Bars
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... +70 °C
Declaration of conformity - ce 2CMT2019-005796
Package level 1 gross weight 12 kg
Product net weight 10.6
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 310 mm
Product net width 186
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A
Cb certificate SE-82316
Package level 1 units box 1 piece
Package level 1 width 280 mm
Connecting capacity main circuit Bar 47 mm²
Rigid Al-Cable 2x240 mm²
Rigid Cu-Cable 240 mm²
dimension 53540919-59
Cqc certificate CQC2007010304256683


CQC2011010304514755
Environmental information 1SFC101004D0202


1SAC200033H0002
Horsepower rating ul/csa (200 V AC) Three Phase 125 hp
(208 V AC) Three Phase 125 hp
(220 ... 240 V AC) Three Phase 150 hp
(440 ... 480 V AC) Three Phase 350 hp
(550 ... 600 V AC) Three Phase 400 hp
Idea granular category code (igcc) 4755 >> Contactors
Dnv gl certificate TAE00001W1
Instructions and manuals 1SFC380023-en
Number of auxiliary contacts no 2
Maximum operating altitude permissible Without Derating 3000 m
Maximum operating voltage ul/csa Main Circuit 1000 V
Lovag certificate SE-0115101
Gl certificate GL_42988-02HH
Minimum order quantity 1 piece
Maximum mechanical switching frequency 300 cycles per hour
mechanical durability 3 million
Number of main contacts no 3
Object classification code Q
Package level 1 ean 7320500217870
Product net height 278
mm
Rated control circuit voltage (uc) 50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Rated frequency (f) Main Circuit 50 / 60 Hz
Prs certificate TE_2092_880423_16
Rated impulse withstand voltage (uimp) Main Circuit 8 kV
Rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (1000 V) 40 °C 600 A
(1000 V) 55 °C 500 A
(1000 V) 70 °C 400 A
(690 V) 40 °C 600 A
(690 V) 55 °C 500 A
(690 V) 70 °C 400 A
Rated operational current ac-3 (ie) (415 V) 55 °C 400 A
(440 V) 55 °C 400 A
(500 V) 55 °C 400 A
(690 V) 55 °C 350 A
(1000 V) 55 °C 155 A
(380 / 400 V) 55 °C 400 A
(220 / 230 / 240 V) 55 °C 400
Operate time Between Coil De-energization and NC Contact Closing 45 ... 55 ms
Between Coil De-energization and NO Contact Opening 48 ... 58 ms
Between Coil Energization and NC Contact Opening 45 ... 115 ms
Between Coil Energization and NO Contact Closing 50 ... 120 ms
Rated making capacity ac-3 10 x Ie AC-3
Rated operational power ac-3 (pe) (415 V) 220 kW
(440 V) 220 kW
(500 V) 250 kW
(690 V) 315 kW
(1000 V) 220 kW
(380 / 400 V) 200 kW
(220 / 230 / 240 V) 110 kW
Rated operational current dc-1 (ie) (110 V) 1-Pole, 40 °C 600 A
(110 V) 2 Poles in Series, 40 °C 600 A
(220 V) 3 Poles in Series, 40 °C 600 A
(600 V) 3 Poles in Series, 40 °C 600 A
Rated operational voltage Main Circuit 1000 V
Reach declaration 2CMT2021-006202
Rated operational current dc-3 (ie) (110 V) 1-Pole, 40 °C 600 A
(110 V) 2 Poles in Series, 40 °C 600 A
(220 V) 3 Poles in Series, 40 °C 600 A
(600 V) 3 Poles in Series, 40 °C 600 A
Resistance to shock acc Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Rated operational current dc-5 (ie) (110 V) 1-Pole, 40 °C 600 A
(110 V) 2 Poles in Series, 40 °C 600 A
(220 V) 3 Poles in Series, 40 °C 600 A
(600 V) 3 Poles in Series, 40 °C 600 A
Ul certificate 20121207-E36588
Ul listing card UL_E36588
Environment
Ccs certificate GB14T00030
Coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 950 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 950 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 885 V·A
Coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Customs tariff number 85364900
EAC certificate 9AKK107046A8618
Rina certificate ELE060313XG_002
Declaration of conformity - ccc 2020980304001300


2020980304001081
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Rmrs certificate 9AKK107045A6978
Short-circuit protective devices gG Type Fuses 630 A
Declaration of conformity - ukca 2CMT2020-006118
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (600 V AC) 550 A
Dnv certificate DNV_E-10966
Lr certificate 16-20064
Number of auxiliary contacts nc 2
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-1) 300 cycles per hour
(AC-2 / AC-4) 60 cycles per hour
(AC-3) 300 cycles per hour
Unspsc 39121529
Rated breaking capacity ac-3 8 x Ie AC-3
Recently viewed
892,66 € excl. VAT
1 089,04 € incl. VAT