All categories
Compare Cart

1SFL527102R1411 - Contactor AF205-40-11-14 250-500V - ABB

Expected in 2-4 weeks
1SFL527102R1411 - Contactor AF205-40-11-14 250-500V - ABB - Contactor AF205-40-11-14 250-500V - ABB - 0
1SFL527102R1411 - Contactor AF205-40-11-14 250-500V - ABB
747,07 € excl. VAT
911,43 € incl. VAT
Text About:
Contactor AF205-40-11-14 250-500V - ABB
911,43 €
SPECIFICATIONS
Additional Information
Bv certificate BV_36353_A0BV
Data sheet, technical information 1SBC100192C0206
E-number (sweden) 3210337
Eclass V11.0 : 27371003
Package level 1 depth / length 238 mm
Product net depth / length 152.5
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Main
Terminal type Main Circuit: Bars
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... +70 °C
Declaration of conformity - ce 2CMT2015-005440
Package level 1 gross weight 3.9 kg
Product net weight 3.3
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 180 mm
Product net width 140
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
Cb certificate SE-82315
Package level 1 units box 1 piece
Package level 1 width 166 mm
Connecting capacity main circuit Flexible 1 x 6 ... 120 mm²
Rigid Al-Cable 1 x 95 ... 185 mm²
Rigid Cu-Cable 1 x 6 ... 150 mm²
dimension 1SFB535001G1122
Cqc certificate CQC2014010304676685
End of life instructions 1SFC100112M0001
Idea granular category code (igcc) 4758 >> Iec Contactors
Dnv gl certificate DNV_E-14043
Number of auxiliary contacts no 1
Maximum operating altitude permissible Without Derating 3000 m
Maximum operating voltage ul/csa Main Circuit 1000 V
Minimum order quantity 1 piece
Maximum mechanical switching frequency 300 cycles per hour
mechanical durability 5 million
Number of main contacts no 4
Object classification code Q
Package level 1 ean 7320500503690
Product net height 195.6
mm
Rated control circuit voltage (uc) 50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Rated frequency (f) Main Circuit 50 Hz
Prs certificate TE_2092_880423_16
Rated impulse withstand voltage (uimp) Main Circuit 8 kV
Rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (1000 V) 40 °C 275 A
(1000 V) 60 °C 250 A
(1000 V) 70 °C 200 A
(690 V) 40 °C 350 A
(690 V) 60 °C 300 A
(690 V) 70 °C 240 A
Rated operational current ac-3 (ie) (415 V) 55 °C 205 A
(440 V) 55 °C 205 A
(380 / 400 V) 55 °C 205 A
(220 / 230 / 240 V) 55 °C 205
Operate time Between Coil De-energization and NO Contact Opening 45 ... 80 ms
Between Coil Energization and NO Contact Closing 25 ... 60 ms
Rated making capacity ac-3 10 x Ie AC-3
Rated operational power ac-3 (pe) (415 V) 110 kW
(440 V) 132 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 55 kW
Rated operational voltage Main Circuit 1000 V
Reach declaration 2CMT2021-006202
Ul certificate 20140925-E73397
Environment
Coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A
Holding at Max. Rated Control Circuit Voltage DC 3.9 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Customs tariff number 85364900
EAC certificate 9AKK107046A8618
Rina certificate ELE060313XG_002
Declaration of conformity - ccc 2020980304001306
Environmental product declaration - epd 1SFC100095D0201
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Rmrs certificate 9AKK107045A6978
Short-circuit protective devices gG Type Fuses 400 A
Circular design principles recyclability rate Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Declaration of conformity - ukca 2CMT2020-006118
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (600 V AC) 250 A
Lr certificate LR_14_70011(E1)
E-number (finland) 3707217
Improved resource efficiency for customers Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line - Achieved
Number of auxiliary contacts nc 1
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-1) 300 cycles per hour
Unspsc 39121529
E-number (norway) 3210337
Group waste to landfill target Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility - Achieved
Rated breaking capacity ac-3 8 x Ie AC-3
Recently viewed
747,07 € excl. VAT
911,43 € incl. VAT
Expected in 2-4 weeks