All categories
Compare Cart

1SFL451022R8000 - CONTACTOR UA110-30-00 220-230V 50Hz - ABB

Expected in 2-4 weeks
1SFL451022R8000 - CONTACTOR UA110-30-00 220-230V 50Hz - ABB - CONTACTOR UA110-30-00 220-230V 50Hz - ABB - 0
1SFL451022R8000 - CONTACTOR UA110-30-00 220-230V 50Hz - ABB
293,74 €
293,74 € incl. VAT
Text About:
CONTACTOR UA110-30-00 220-230V 50Hz - ABB
293,74 €
SPECIFICATIONS
Additional Information
Data sheet, technical information 1SBC101145L0202
Eclass V11.0 : 27371006
Package level 1 depth / length 265 mm
Product net depth / length 123.5
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Main
Terminal type Cable Clamp
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Declaration of conformity - ce 2CMT2015-005436
Package level 1 gross weight 2 kg
Product net weight 1.8
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC001079 - Capacitor magnet contactor
Etim 5 EC001079 - Capacitor magnet contactor
Package level 1 height 162 mm
Product net width 90
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Cb certificate SE-72473
Package level 1 units box 1 piece
Package level 1 width 130 mm
Connecting capacity main circuit Bar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 2 x 6 ... 65 mm²
Cqc certificate CQC2003010304088242


CQC2009010304353513
Environmental information 1SFC101001D0201
Idea granular category code (igcc) 4756 >> Capacitor magnet contactor
Instructions and manuals 5309660-60
Maximum operating altitude permissible Without Derating 3000 m
Maximum operating voltage ul/csa Main Circuit 600 V
Minimum order quantity 1 piece
Maximum mechanical switching frequency 3600 cycles per hour
mechanical durability 10 million
Number of main contacts no 3
Object classification code Q
Package level 1 ean 7320500188552
Product net height 148
mm
Rated operational power ac-6b (pe) (230 / 240 V) 40 °C, 50 / 60 Hz 40 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 40 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 35 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 75 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 65 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 70 kvar
(440 V) 40 °C, 50 / 60 Hz 75 kvar
(440 V) 55 °C, 50 / 60 Hz 75 kvar
(440 V) 70 °C, 50 / 60 Hz 70 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 80 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 80 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 75 kvar
(690 V) 40 °C, 50 / 60 Hz 90 kvar
(690 V) 55 °C, 50 / 60 Hz 90 kvar
(690 V) 70 °C, 50 / 60 Hz 85 kvar
Rated control circuit voltage (uc) 50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Rated frequency (f) Main Circuit 50 / 60 Hz
Rated impulse withstand voltage (uimp) Main Circuit 8 kV
Rated insulation voltage (ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Operate time Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Rated operational voltage Main Circuit 1000 V
Reach declaration 2CMT2021-006202
Resistance to shock acc Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Environment
Coil consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Coil operating limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting capacity auxiliary circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting terminals (delivered in open position) main poles M8 hexagon socket screw with single connector
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Customs tariff number 85364900
Culus certificate 20160916- E36588
Declaration of conformity - ccc 2020980304001551


2020980304001055
ETIM - 8 EC001079 - Capacitor contactor
Etim 6 EC001079 - Capacitor contactor
Declaration of conformity - ukca 2CMT2020-006118
Etim 7 EC001079 - Capacitor contactor
Rohs information 2CMT2021-006277
Maximum electrical switching frequency 240 cycles per hour
Unspsc 39121529
Recently viewed
293,74 €
293,74 € incl. VAT
Expected in 2-4 weeks