All categories
Compare Cart

1SDA100552R1 - XT5N 400 BREAKING PART 4p F F - ABB

Expected in 2-4 weeks
1SDA100552R1 - XT5N 400 BREAKING PART 4p F F - ABB - XT5N 400 BREAKING PART 4p F F - ABB - 0
1SDA100552R1 - XT5N 400 BREAKING PART 4p F F - ABB - XT5N 400 BREAKING PART 4p F F - ABB - 1
1SDA100552R1 - XT5N 400 BREAKING PART 4p F F - ABB - XT5N 400 BREAKING PART 4p F F - ABB - 2
1SDA100552R1 - XT5N 400 BREAKING PART 4p F F - ABB
365,25 € excl. VAT
445,60 € incl. VAT
Text About:
XT5N 400 BREAKING PART 4p F F - ABB
445,60 €
SPECIFICATIONS
Additional Information
Data sheet, technical information 1SDC210100D0206


1SDC210099D0206
Eclass V11.1 : 27370409
Package level 1 depth / length 285 mm
EAN 8056221006286
Product net depth / length 103.5
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Weee category 5. Small Equipment (No External Dimension More Than 50 cm)
Main
Product Name Moulded Case Circuit Breaker
Product type Breaking Part
version F
Complementary
Declaration of conformity - ce 9AKK107680A2824
Package level 1 gross weight 4.5 kg
Product net weight 4.15
kg
Conflict minerals reporting template (cmrt) 9AKK108467A5658
Package level 1 height 240 mm
Product net width 186
mm
[ics] rated service breaking capacity (220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 2 Poles in Series 25 kA
Package level 1 units box 1 piece
Package level 1 width 248 mm
Environmental information 9AKK107991A8215


9AKK108467A6707
Instructions and manuals 1SDH002011A1001
Order multiple 1 piece
Minimum order quantity 1 piece
Product main type SACE Tmax XT
mechanical durability 240 cycles per hour
20000 cycle
Object classification code Q
electrical durability 120 cycles per hour
7000 cycle
Package level 1 ean 8056221006286
Product net height 205
mm
Rated short-time withstand current low voltage (icw) 5 kA
Rated uninterrupted current (iu) 400 A
Rated impulse withstand voltage (uimp) 8 kV
Rated insulation voltage (ui) 1000 V
Short-circuit performance level N
Rated operational voltage 690 V AC
750 V DC
Reach declaration 9AKK108466A1425
Sub-type XT5
Poles description 4
Terminal connection type Front
Rated ultimate short-circuit breaking capacity (icu) (220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 2 Poles in Series 25 kA
Environment
Customs tariff number 85389099
ETIM - 8 EC000228 - Power circuit-breaker for trafo/generator/installation protection
Etim 6 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
standards IEC
Etim 7 EC000228 - Power circuit-breaker for trafo/generator/installation protection
Scip 9ce24c01-0946-4cf5-b5d7-1fbf6fa704b3 Italy (IT)
E-number (finland) 3641397
Rohs information 9AKK108466A1424
Toxic substances control act - tsca 9AKK108467A8326
Recently viewed
365,25 € excl. VAT
445,60 € incl. VAT
Expected in 2-4 weeks