Additional Information
Data sheet, technical information
1SDC210100D0206
1SDC210099D0206
Eclass
V11.1 : 27370409
Package level 1 depth / length
168 mm
EAN
8015644695927
Product net depth / length
82.5
mm
Rohs status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Weee category
5. Small Equipment (No External Dimension More Than 50 cm)
Main
Product Name
Moulded Case Circuit Breaker
Product type
Automatic Circuit Breaker
version
F
Complementary
Declaration of conformity - ce
9AKK106713A5529
Opening time
CB with SOR 15 ms
CB with UVR 15 ms
Package level 1 gross weight
3.023 kg
Product net weight
3.5
kg
[in] rated current
250 A
Cad dimensional drawing
1SDH001295R0677
Conflict minerals reporting template (cmrt)
9AKK108467A5658
Etim 4
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
Etim 5
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
Package level 1 height
210 mm
Product net width
140
mm
[ics] rated service breaking capacity
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
Package level 1 units
box 1 piece
Package level 1 width
145 mm
dimension
1SDH000722R0100
Environmental information
9AKK107991A8215
9AKK108467A6707
Instructions and manuals
1SDH000722R0001
Order code us and canada
XT4NE4250BFF000XXX
Order multiple
1 piece
Gl certificate
1SDL000163R0095
Minimum order quantity
1 piece
Product main type
SACE Tmax XT
mechanical durability
240 cycles per hour
25000 cycle
Object classification code
Q
electrical durability
120 cycles per hour
8000 cycle
Package level 1 ean
8015644695927
Product net height
160
mm
Rated frequency (f)
50 / 60 Hz
Rated uninterrupted current (iu)
250 A
Rated impulse withstand voltage (uimp)
8 kV
Rated insulation voltage (ui)
1000 V
Rated voltage (ur)
690 V
Power loss
at Rated Operating Conditions per Pole 16.44 W
Release
TMA
Short-circuit performance level
N
Rated operational voltage
690 V AC
750 V DC
Rated instantaneous short-circuit current setting (ii)
1250…2500 A
Reach declaration
9AKK108466A1425
Sub-type
XT4
Poles description
4
Terminal connection type
Front
Wiring diagram
1SDM000068R0001
Ul certificate
No certification needed
Rated ultimate short-circuit breaking capacity (icu)
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
Setting range
175...250 A
Environment
Atex certificate
No certification needed
Circuit breaker type to be associated
Power Distribution
Customs tariff number
85362090
Release type
TM
Current type
AC/DC
ETIM - 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Etim 6
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
Mechanical drawings
1SDH000722R0100
standards
IEC
Etim 7
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Lr certificate
1SDL000163R0100
Scip
825ef000-86ef-4390-b3bc-469b4df74414 Italy (IT)
Rohs information
9AKK108466A1424
Toxic substances control act - tsca
9AKK108467A8326
Unspsc
39120000
Vde certificate
No certification needed