Additional Information
Data sheet, technical information
1SCC301020C0201
E-number (sweden)
3171061
Eclass
V11.1 : 27371403
Package level 1 depth / length
244 mm
9.6 in
Product net depth / length
73
mm
Rohs status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Special functions
No
Weee category
5. Small Equipment (No External Dimension More Than 50 cm)
Main
Terminal type
Screw Terminals
Mounting type
Base mounting
degree of protection
Front IP20
Complementary
Declaration of conformity - ce
1SCC301210D2701
Handle type
Handle and shaft included
Package level 1 gross weight
1.3 kg
2.8 lb
Product net weight
1.2
kg
Conflict minerals reporting template (cmrt)
9AKK108467A5658
Etim 5
EC000216 - Switch disconnector
Package level 1 height
96 mm
3.8 in
Position of line terminals
Top In - Bottom Out
Bottom In - Top Out
Product net width
150
mm
Cable cross section
Cu 10 ... 70 mm²
Country of origin
Finland (FI)
Distance between phases
Standard
Fourth pole position
Right Side
Handle colour
Black
Package level 1 units
box 1 piece
Lock type
Yes
Package level 1 width
160 mm
6.3 in
tightening torque
acc. IEC 60947-1 6 N·m
Fourth pole type
Switched - Simultaneous Function
Environmental information
1SCC301267D0201
Horsepower rating ul/csa
(240 V AC) Single Phase 20 Hp
(440 ... 480 V AC) Single Phase 30 Hp
Dnv gl certificate
1SCC301174D0204
Instructions and manuals
1SCC301089M0204
Maximum operating voltage ul/csa
600 V
Minimum order quantity
1 piece
mechanical durability
20000
Object classification code
Q
Rated conditional short-circuit current (inc)
(200 A fuse, 500 V) 100 kA
(200 A fuse, 690 V) 50 kA
Package level 1 ean
6417019638713
Pollution degree
3
Product net height
130
mm
Rated short-time withstand current low voltage (icw)
for 1 s 4 kA
Rated operational current ac-21a (ie)
(380 ... 415 V) 160 A
(500 V) 160 A
(690 V) 160 A
Rated impulse withstand voltage (uimp)
12 kV
Rated operational current ac-22a (ie)
(380 ... 415 V) 160 A
(500 V) 160 A
(690 V) 160 A
Rated insulation voltage (ui)
acc. to IEC/EN 60664-1 1000 V
Rated operational current ac-23a (ie)
(380 ... 415 V) 160 A
(500 V) 160 A
(690 V) 160 A
Rated operational power ac-23a (pe)
(220 ... 240 V) 45 kW
(400 ... 415 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
Operating mode
Front and side operated
Rated short-circuit making capacity (icm)
(690 V) 12 kA
Power loss
at Rated Operating Conditions per Pole 6.5 W
Switches operating mechanism
Mechanism at the End of the Switch
04 (Left Side)
Rated operational voltage
Main Circuit 1000 V
Reach declaration
1SCC011021D0201
Poles description
4
Tightening torque ul/csa
53 in·lb
Ul certificate
cULus certificate OT160G
Environment
Ampere rating
125 A
Atex certificate
No certification needed
Conventional free-air thermal current (ith)
Θ = 40 °C 160 A
Customs tariff number
85365080
Conventional thermal current (ithe)
Fully Enclosed 160 A
ETIM - 8
EC000216 - Switch disconnector
Etim 6
EC000216 - Switch disconnector
Mechanical drawings
OT160G4_model.igs
standards
IEC 60947-3 / UL 98 / CSA C22.2 NO.4
Etim 7
EC000216 - Switch disconnector
Etim 9
EC000216 - Switch disconnector (low voltage)
Scip
0f3f7427-49c7-4e78-bb73-a737862f1a86 Finland (FI)
E-number (finland)
3638770
Rohs information
1SCC011020D0201
Vde certificate
No certification needed