All categories
Compare Cart

1SBL387001R1200 - AF65-30-00-12 - ABB

Expected in 2-4 weeks
1SBL387001R1200 - AF65-30-00-12 - ABB - AF65-30-00-12 - ABB - 0
1SBL387001R1200 - AF65-30-00-12 - ABB
153,81 € excl. VAT
187,65 € incl. VAT
Text About:
AF65-30-00-12 - ABB
187,65 €
SPECIFICATIONS
Additional Information
Bv certificate BV_2634H36994A
E-number (sweden) 3210043
Eclass V11.0 : 27371003
Package level 1 depth / length 150 mm
Product net depth / length 111
mm
Rohs status Following EU Directive 2011/65/EU
Mounting by screws (not supplied) 2 x M4 or 2 x M6 screws placed diagonally
Resistance to vibrations acc 5 ... 300 Hz 3 g closed position / 3 g open position
Main
Terminal type Screw Terminals
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Ccc certificate CCC_2012010304589737


CCC_2015010304824714
Declaration of conformity - ce 1SBD250000U1000
Package level 1 gross weight 1.07 kg
Product net weight 0.97
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 97 mm
Product net width 55
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Cb certificate CB_SE-108889A1
Package level 1 units box 1 piece
Connecting capacity control circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Package level 1 width 150 mm
Connecting capacity main circuit Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Package level 2 depth / length 300 mm
Cqc certificate CQC2015010304824714


CQC2012010304589737
Environmental information 1SBD250168E1000


1SBC100222M0201
Package level 2 gross weight 10.7 kg
Horsepower rating ul/csa (120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Package level 2 height 300 mm
Idea granular category code (igcc) 4758 >> Iec Contactors
Package level 2 units box 10 piece
Instructions and manuals 1SBC101036M6801
Package level 2 width 250 mm
Package level 3 units 240 piece
Maximum operating altitude permissible Without Derating 3000 m
Gl certificate DNV-GL_TAE00001AF-3
Minimum order quantity 1 piece
Maximum mechanical switching frequency 3600 cycles per hour
wire stripping length Main Circuit 16 mm
Number of main contacts no 3
Object classification code Q
Package level 1 ean 3471523132627
Product net height 125.5
mm
Rated control circuit voltage (uc) 50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Rated frequency (f) Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated impulse withstand voltage (uimp) 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated operational current ac-3 (ie) (415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Operate time Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Rated operational power ac-3 (pe) (400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated operational current dc-1 (ie) (110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
Rated operational voltage Main Circuit 690 V
Reach declaration 2CMT2021-006202
Rated operational current dc-3 (ie) (110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
Resistance to shock acc Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Rated operational current ac-3e (ie) (415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated operational current dc-5 (ie) (110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
Tightening torque ul/csa Control Circuit 11 in·lb
Main Circuit 35 in·lb
Rated operational power ac-3e (pe) (415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Ul certificate UL_20130301_E312527_14_1
Ul listing card UL_E312527
Environment
Climatic withstand Category B according to IEC 60947-1 Annex Q
Connecting capacity control circuit ul/csa Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Customs tariff number 85364900
EAC certificate EAC_RU_FRME77B03447
Rina certificate RINA_ELE084013XG
Connecting capacity main circuit ul/csa Rigid Stranded 1/2x 10-2 AWG
Declaration of conformity - ccc 2020980304001256


2020980304001074
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Rmrs certificate RMRS_1802705280
Declaration of conformity - ukca 1SBD250031U1000
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (600 V AC) 90 A
Kc certificate KC_HW02016-15003C
Lr certificate LRS_1300087E1
E-number (finland) 3707047
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Unspsc 39121529
Recently viewed
153,81 € excl. VAT
187,65 € incl. VAT
Expected in 2-4 weeks