All categories
Compare Cart

1SBL177201R4100 - AF16-40-00-41 - ABB

Expected in 2-4 weeks
1SBL177201R4100 - AF16-40-00-41 - ABB - AF16-40-00-41 - ABB - 0
1SBL177201R4100 - AF16-40-00-41 - ABB
excl. VAT
incl. VAT
Text About:
AF16-40-00-41 - ABB
SPECIFICATIONS
Additional Information
Bv certificate BV_2634H24898B0
Eclass V11.0 : 27371003
Package level 1 depth / length 79 mm
Product net depth / length 77
mm
Rohs status Following EU Directive 2011/65/EU
Mounting by screws (not supplied) 2 x M4 screws placed diagonally
Resistance to vibrations acc 5 ... 300 Hz 4 g closed position / 2 g open position
Main
Terminal type Screw Terminals
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Complementary
Ambient air temperature Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Ccc certificate CCC_2010010304445624
Declaration of conformity - ce 1SBD250001U1000
Package level 1 gross weight 0.27 kg
Product net weight 0.27
kg
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 47 mm
Product net width 45
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Cb certificate CB_SE-108879
Package level 1 units box 1 piece
Connecting capacity auxiliary circuit ul/csa Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Connecting capacity control circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Package level 1 width 87 mm
Connecting capacity main circuit Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Package level 2 depth / length 300 mm
Cqc certificate CQC2010010304445624


CQC2020010304298240
Environmental information 1SBD250147E1000
Package level 2 gross weight 14.58 kg
Package level 2 height 315 mm
Idea granular category code (igcc) 4758 >> Iec Contactors
Package level 2 units box 27 piece
Instructions and manuals 1SBC101027M6801
Package level 2 width 250 mm
Package level 3 units 1296 piece
Maximum operating altitude permissible Without Derating 3000 m
Gl certificate DNV-GL_TAE00001AF-3
Minimum order quantity 1 piece
Maximum mechanical switching frequency 3600 cycles per hour
wire stripping length Control Circuit 10 mm
Main Circuit 10 mm
Number of main contacts no 4
Object classification code Q
Package level 1 ean 3471523115101
Product net height 86
mm
Rated control circuit voltage (uc) 50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation -
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Rated frequency (f) Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated impulse withstand voltage (uimp) 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (690 V) 40 °C 30 A
(690 V) 60 °C 30 A
(690 V) 70 °C 26 A
Rated operational current ac-3 (ie) (415 V) 60 °C 18 A
(440 V) 60 °C 18 A
(500 V) 60 °C 15 A
(690 V) 60 °C 10.5 A
(380 / 400 V) 60 °C 18 A
(220 / 230 / 240 V) 60 °C 18 A
Operate time Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Rated operational power ac-3 (pe) (400 V) 7.5 kW
(415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated operational current dc-1 (ie) (110 V) 1-Pole, 40 °C 20 A
(110 V) 1-Pole, 60 °C 20 A
(110 V) 1-Pole, 70 °C 20 A
(110 V) 2 Poles in Series, 40 °C 30 A
(110 V) 2 Poles in Series, 60 °C 30 A
(110 V) 2 Poles in Series, 70 °C 26 A
(110 V) 3 Poles in Series, 40 °C 30 A
(110 V) 3 Poles in Series, 60 °C 30 A
(110 V) 3 Poles in Series, 70 °C 26 A
(110 V) 4 Poles in Series, 40 °C 30 A
(110 V) 4 Poles in Series, 60 °C 30 A
(110 V) 4 Poles in Series, 70 °C 26 A
(220 V) 2 Poles in Series, 40 °C 20 A
(220 V) 2 Poles in Series, 60 °C 20 A
(220 V) 2 Poles in Series, 70 °C 20 A
(220 V) 3 Poles in Series, 40 °C 30 A
(220 V) 3 Poles in Series, 60 °C 30 A
(220 V) 3 Poles in Series, 70 °C 26 A
(220 V) 4 Poles in Series, 40 °C 30 A
(220 V) 4 Poles in Series, 60 °C 30 A
(220 V) 4 Poles in Series, 70 °C 26 A
(440 V) 4 Poles in Series, 40 °C 20 A
(440 V) 4 Poles in Series, 60 °C 20 A
(440 V) 4 Poles in Series, 70 °C 20 A
(72 V) 1-Pole, 40 °C 30 A
(72 V) 1-Pole, 60 °C 30 A
(72 V) 1-Pole, 70 °C 26 A
(72 V) 2 Poles in Series, 40 °C 30 A
(72 V) 2 Poles in Series, 60 °C 30 A
(72 V) 2 Poles in Series, 70 °C 26 A
(72 V) 3 Poles in Series, 40 °C 30 A
(72 V) 3 Poles in Series, 60 °C 30 A
(72 V) 3 Poles in Series, 70 °C 26 A
(72 V) 4 Poles in Series, 40 °C 30 A
(72 V) 4 Poles in Series, 60 °C 30 A
(72 V) 4 Poles in Series, 70 °C 26 A
Rated operational voltage Main Circuit 690 V
Rated operational current dc-3 (ie) (110 V) 1-Pole, 40 °C 8 A
(110 V) 1-Pole, 60 °C 8 A
(110 V) 1-Pole, 70 °C 8 A
(110 V) 2 Poles in Series, 40 °C 30 A
(110 V) 2 Poles in Series, 60 °C 30 A
(110 V) 2 Poles in Series, 70 °C 26 A
(110 V) 3 Poles in Series, 40 °C 30 A
(110 V) 3 Poles in Series, 60 °C 30 A
(110 V) 3 Poles in Series, 70 °C 26 A
(110 V) 4 Poles in Series, 40 °C 30 A
(110 V) 4 Poles in Series, 60 °C 30 A
(110 V) 4 Poles in Series, 70 °C 26 A
(220 V) 2 Poles in Series, 40 °C 8 A
(220 V) 2 Poles in Series, 60 °C 8 A
(220 V) 2 Poles in Series, 70 °C 8 A
(220 V) 3 Poles in Series, 40 °C 30 A
(220 V) 3 Poles in Series, 60 °C 30 A
(220 V) 3 Poles in Series, 70 °C 26 A
(220 V) 4 Poles in Series, 40 °C 30 A
(220 V) 4 Poles in Series, 60 °C 30 A
(220 V) 4 Poles in Series, 70 °C 26 A
(440 V) 4 Poles in Series, 40 °C 8 A
(440 V) 4 Poles in Series, 60 °C 8 A
(440 V) 4 Poles in Series, 70 °C 8 A
(72 V) 1-Pole, 40 °C 30 A
(72 V) 1-Pole, 60 °C 30 A
(72 V) 1-Pole, 70 °C 26 A
(72 V) 2 Poles in Series, 40 °C 30 A
(72 V) 2 Poles in Series, 60 °C 30 A
(72 V) 2 Poles in Series, 70 °C 26 A
(72 V) 3 Poles in Series, 40 °C 30 A
(72 V) 3 Poles in Series, 60 °C 30 A
(72 V) 3 Poles in Series, 70 °C 26 A
(72 V) 4 Poles in Series, 40 °C 30 A
(72 V) 4 Poles in Series, 60 °C 30 A
(72 V) 4 Poles in Series, 70 °C 26 A
Resistance to shock acc Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Rated operational current dc-5 (ie) (110 V) 1-Pole, 40 °C 4 A
(110 V) 1-Pole, 60 °C 4 A
(110 V) 1-Pole, 70 °C 4 A
(110 V) 2 Poles in Series, 40 °C 20 A
(110 V) 2 Poles in Series, 60 °C 20 A
(110 V) 2 Poles in Series, 70 °C 20 A
(110 V) 3 Poles in Series, 40 °C 30 A
(110 V) 3 Poles in Series, 60 °C 30 A
(110 V) 3 Poles in Series, 70 °C 26 A
(110 V) 4 Poles in Series, 40 °C 30 A
(110 V) 4 Poles in Series, 60 °C 30 A
(110 V) 4 Poles in Series, 70 °C 26 A
(220 V) 2 Poles in Series, 40 °C 4 A
(220 V) 2 Poles in Series, 60 °C 4 A
(220 V) 2 Poles in Series, 70 °C 4 A
(220 V) 3 Poles in Series, 40 °C 16 A
(220 V) 3 Poles in Series, 60 °C 16 A
(220 V) 3 Poles in Series, 70 °C 16 A
(220 V) 4 Poles in Series, 40 °C 20 A
(220 V) 4 Poles in Series, 60 °C 20 A
(220 V) 4 Poles in Series, 70 °C 20 A
(440 V) 4 Poles in Series, 40 °C 4 A
(440 V) 4 Poles in Series, 60 °C 4 A
(440 V) 4 Poles in Series, 70 °C 4 A
(72 V) 1-Pole, 40 °C 16 A
(72 V) 1-Pole, 60 °C 16 A
(72 V) 1-Pole, 70 °C 16 A
(72 V) 2 Poles in Series, 40 °C 30 A
(72 V) 2 Poles in Series, 60 °C 30 A
(72 V) 2 Poles in Series, 70 °C 26 A
(72 V) 3 Poles in Series, 40 °C 30 A
(72 V) 3 Poles in Series, 60 °C 30 A
(72 V) 3 Poles in Series, 70 °C 26 A
(72 V) 4 Poles in Series, 40 °C 30 A
(72 V) 4 Poles in Series, 60 °C 30 A
(72 V) 4 Poles in Series, 70 °C 26 A
Tightening torque ul/csa Control Circuit 11 in·lb
Main Circuit 13 in·lb
Ul certificate UL_20171228-E319322_3_1
Ul listing card UL_E319322
Environment
Climatic withstand Category B according to IEC 60947-1 Annex Q
Connecting capacity auxiliary circuit Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting capacity control circuit ul/csa Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Customs tariff number 85364900
EAC certificate EAC_RU_FRME77B03447
Rina certificate RINA_ELE240318XG
Connecting capacity main circuit ul/csa Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
Declaration of conformity - ccc 2020980304001253


2020980304001082
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Gost certificate GOST_POCCFR.ME77.B07175.pdf
Rmrs certificate RMRS_1802705280
standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Declaration of conformity - ukca 1SBD250032U1000
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (600 V AC) 30 A
Kc certificate KC_HW02016-15008C
Lr certificate LRS_1300087E1
Rohs information 1SBD250001U1000
Maximum electrical switching frequency (AC-1) 600 cycles per hour
Unspsc 39121529
Recently viewed
excl. VAT
incl. VAT
Expected in 2-4 weeks