All categories
Compare Cart

1SBL157001R1401 - AF12-30-01-14 - ABB

Pending restock
1SBL157001R1401 - AF12-30-01-14 - ABB - AF12-30-01-14 - ABB - 0
1SBL157001R1401 - AF12-30-01-14 - ABB
23,15 € excl. VAT
28,71 € incl. VAT
Text About:
AF12-30-01-14 - ABB
28,71 €
SPECIFICATIONS
Additional Information
Bv certificate BV_2634H24898B0
E-number (sweden) 3211367
Eclass V11.0 : 27371003
Package level 1 depth / length 79 mm
Product net depth / length 77
mm
Rohs status Following EU Directive 2011/65/EU
Mounting by screws (not supplied) 2 x M4 screws placed diagonally
Resistance to vibrations acc 5 ... 300 Hz 4 g closed position / 2 g open position
Main
Terminal type Screw Terminals
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Complementary
Ambient air temperature Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Ccc certificate CCC_2010010304445624
Declaration of conformity - ce 1SBD250000U1000
Package level 1 gross weight 0.31 kg
Product net weight 0.31
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000066 - Magnet contactor, AC-switching
Etim 5 EC000066 - Magnet contactor, AC-switching
Package level 1 height 47 mm
Product net width 45
mm
[ics] rated service breaking capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Cb certificate CB_SE-108879
Package level 1 units box 1 piece
Connecting capacity auxiliary circuit ul/csa Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Connecting capacity control circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Package level 1 width 87 mm
Connecting capacity main circuit Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Package level 2 depth / length 300 mm
Cqc certificate CQC2010010304445624


CQC2020010304298240
Continuous current rating nema 18 A
Environmental information 1SBD250147E1000


1SBC100222M0201
Package level 2 gross weight 8.37 kg
Horsepower rating ul/csa (120 V AC) Single Phase 1 hp
(200 ... 208 V AC) Three Phase 3 hp
(220 ... 240 V AC) Three Phase 3 hp
(240 V AC) Single Phase 2 hp
(440 ... 480 V AC) Three Phase 7-1/2 hp
(550 ... 600 V AC) Three Phase 10 hp
Package level 2 height 315 mm
Idea granular category code (igcc) 4758 >> Iec Contactors
Package level 2 units box 27 piece
Instructions and manuals 1SBC101027M6801
Package level 2 width 250 mm
Package level 3 units 1296 piece
Horsepower rating nema (115 V AC) Single Phase 1 Hp
(200 V AC) Three Phase 3 Hp
(230 V AC) Single Phase 2 Hp
(230 V AC) Three Phase 3 Hp
(460 V AC) Three Phase 5 Hp
(575 V AC) Three Phase 5 Hp
Maximum operating altitude permissible Without Derating 3000 m
Gl certificate DNV-GL_TAE00001AF-3
Minimum order quantity 1 piece
Maximum mechanical switching frequency 3600 cycles per hour
wire stripping length Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Number of main contacts no 3
Object classification code Q
Package level 1 ean 3471523110441
Product net height 86
mm
Rated control circuit voltage (uc) 50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Rated short-time withstand current low voltage (icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Rated frequency (f) Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated impulse withstand voltage (uimp) 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated operational current ac-1 (ie) (690 V) 40 °C 28 A
(690 V) 60 °C 28 A
(690 V) 70 °C 24 A
Rated operational current ac-3 (ie) (415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
Operate time Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Rated operational power ac-3 (pe) (400 V) 5.5 kW
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
Rated operational current ac-15 (ie) (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated operational current dc-13 (ie) (24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated operational current dc-1 (ie) (110 V) 1-Pole, 40 °C 15 A
(110 V) 1-Pole, 60 °C 15 A
(110 V) 1-Pole, 70 °C 15 A
(110 V) 2 Poles in Series, 40 °C 27 A
(110 V) 2 Poles in Series, 60 °C 27 A
(110 V) 2 Poles in Series, 70 °C 24 A
(110 V) 3 Poles in Series, 40 °C 27 A
(110 V) 3 Poles in Series, 60 °C 27 A
(110 V) 3 Poles in Series, 70 °C 24 A
(220 V) 2 Poles in Series, 40 °C 15 A
(220 V) 2 Poles in Series, 60 °C 15 A
(220 V) 2 Poles in Series, 70 °C 15 A
(220 V) 3 Poles in Series, 40 °C 27 A
(220 V) 3 Poles in Series, 60 °C 27 A
(220 V) 3 Poles in Series, 70 °C 24 A
(72 V) 1-Pole, 40 °C 27 A
(72 V) 1-Pole, 60 °C 27 A
(72 V) 1-Pole, 70 °C 24 A
(72 V) 2 Poles in Series, 40 °C 27 A
(72 V) 2 Poles in Series, 60 °C 27 A
(72 V) 2 Poles in Series, 70 °C 24 A
(72 V) 3 Poles in Series, 40 °C 27 A
(72 V) 3 Poles in Series, 60 °C 27 A
(72 V) 3 Poles in Series, 70 °C 24 A
Rated operational voltage Auxiliary Circuit 690 V
Main Circuit 690 V
Reach declaration 2CMT2021-006202
Rated operational current dc-3 (ie) (110 V) 1-Pole, 40 °C 7 A
(110 V) 1-Pole, 60 °C 7 A
(110 V) 1-Pole, 70 °C 7 A
(110 V) 2 Poles in Series, 40 °C 27 A
(110 V) 2 Poles in Series, 60 °C 27 A
(110 V) 2 Poles in Series, 70 °C 24 A
(110 V) 3 Poles in Series, 40 °C 27 A
(110 V) 3 Poles in Series, 60 °C 27 A
(110 V) 3 Poles in Series, 70 °C 24 A
(220 V) 2 Poles in Series, 40 °C 7 A
(220 V) 2 Poles in Series, 60 °C 7 A
(220 V) 2 Poles in Series, 70 °C 7 A
(220 V) 3 Poles in Series, 40 °C 27 A
(220 V) 3 Poles in Series, 60 °C 27 A
(220 V) 3 Poles in Series, 70 °C 24 A
(72 V) 1-Pole, 40 °C 27 A
(72 V) 1-Pole, 60 °C 27 A
(72 V) 1-Pole, 70 °C 24 A
(72 V) 2 Poles in Series, 40 °C 27 A
(72 V) 2 Poles in Series, 60 °C 27 A
(72 V) 2 Poles in Series, 70 °C 24 A
(72 V) 3 Poles in Series, 40 °C 27 A
(72 V) 3 Poles in Series, 60 °C 27 A
(72 V) 3 Poles in Series, 70 °C 24 A
Resistance to shock acc Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Rated operational current ac-3e (ie) (415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
Rated operational current dc-5 (ie) (110 V) 1-Pole, 40 °C 4 A
(110 V) 1-Pole, 60 °C 4 A
(110 V) 1-Pole, 70 °C 4 A
(110 V) 2 Poles in Series, 40 °C 15 A
(110 V) 2 Poles in Series, 60 °C 15 A
(110 V) 2 Poles in Series, 70 °C 15 A
(110 V) 3 Poles in Series, 40 °C 27 A
(110 V) 3 Poles in Series, 60 °C 27 A
(110 V) 3 Poles in Series, 70 °C 24 A
(220 V) 2 Poles in Series, 40 °C 4 A
(220 V) 2 Poles in Series, 60 °C 4 A
(220 V) 2 Poles in Series, 70 °C 4 A
(220 V) 3 Poles in Series, 40 °C 12 A
(220 V) 3 Poles in Series, 60 °C 12 A
(220 V) 3 Poles in Series, 70 °C 12 A
(72 V) 1-Pole, 40 °C 12 A
(72 V) 1-Pole, 60 °C 12 A
(72 V) 1-Pole, 70 °C 12 A
(72 V) 2 Poles in Series, 40 °C 27 A
(72 V) 2 Poles in Series, 60 °C 27 A
(72 V) 2 Poles in Series, 70 °C 24 A
(72 V) 3 Poles in Series, 40 °C 27 A
(72 V) 3 Poles in Series, 60 °C 27 A
(72 V) 3 Poles in Series, 70 °C 24 A
Tightening torque ul/csa Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Rated operational power ac-3e (pe) (415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
Ul certificate UL-US-2150887-5


UL-CA-2142658-5
Ul listing card E312527
Environment
Climatic withstand Category B according to IEC 60947-1 Annex Q
Connecting capacity auxiliary circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting capacity control circuit ul/csa Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Conventional free-air thermal current (ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Customs tariff number 85364900
EAC certificate EAC_RU_FRME77B03447
Rina certificate RINA_ELE240318XG
Connecting capacity main circuit ul/csa Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
Declaration of conformity - ccc 2020980304001253


2020980304001082
ETIM - 8 EC000066 - Power contactor, AC switching
Etim 6 EC000066 - Power contactor, AC switching
Gost certificate GOST_POCCFR.ME77.B07175.pdf
Rmrs certificate RMRS_1802705280
standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Declaration of conformity - ukca 1SBD250031U1000
Etim 7 EC000066 - Power contactor, AC switching
General use rating ul/csa (600 V AC) 28 A
Kc certificate KC_HW02016-15005C
Lr certificate LRS_1300087E1
E-number (finland) 3706226
Number of auxiliary contacts nc 1
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Unspsc 39121529
About this product

The 1SBL157001R1401 - AF12-30-01-14 is developed to meet the requirements of trade buyers, such as installers, circuit experts, maintenance service providers, and primary equipment makers. 1SBL157001R1401 furnishes first-rate efficiency and beneficence for developers in the electrical engineering industry. This AF12-30-01-14 and other AF12 from ABB can be ordered at the most affordable rate and delivery schedule through baltelec.eu, a reputable merchant supporting professionals in their gathering needs.

Users who have purchased ABB AF12 have habitually appreciated the creator's trustworthiness. It has been noted that the superior capability of 1SBL157001R1401 - AF12-30-01-14 extends to a variety of operations. Its excellent properties make it great solution for multiple purposes, assuring the success of your industrial, tertiary, and automation ventures.

Our professionals specializes in addressing industrial and tertiary professionals’ needs. We recognize the distinct needs and standards of our partners in the field. By working with Baltelec team, your team obtain access to the optimal pricing and delivery schedule of premium products like 1SBL157001R1401 - AF12-30-01-14 from ABB at an economical price. Registered customers benefit from exclusive discounts and preferred assistance.

Do not hesitate and procure 1SBL157001R1401 - AF12-30-01-14 at our safe and streamlined e-commerce site. Don't delay in making this sensible plan that warrants the top quality and adheres to the special requirements of customers like your business.

If there are any worries or concerns about 1SBL157001R1401 - AF12-30-01-14 or any other ABB products, reach out to us or refer to our Knowledge base section below. We have compiled answers to habitual questions to guide you further in making an well-informed decision about industrial and tertiary electrical components.

Remember, 1SBL157001R1401 - AF12-30-01-14 from ABB is reliable, reasonable, and better to other brands in the AF12 category. Make it a part of your infrastructure right now. Acquire at BALTELEC, your trusted partner for all your professional electrical equipment and automation needs.

In our Baltelec.eu online store you will come across AF12-30-01-14 - 1SBL157001R1401 worth 28.25 €, which will be a trustworthy and fashionable solution for your necessities. This product is produced by the ABB brand using the freshest technologies and adheres to the leading standards of defense and efficacy. We deliver goods from the AF12 category that mix longevity and efficacy, which is an excellent choice for various functions. Irrespective of whether you crave equipment for small production or for specialized industrial utilization, AF12-30-01-14 will be a constant adjunct in your project.

Baltelec attempts to make the obtaining process as comfortable and fast as achievable for our patrons. We offer detailed descriptions and high-quality illustrations of AF12-30-01-14 so that you can make an educated choice. A team of adepts is always ready to help you with any issues in the AF12 section tied to the choice and use of wares. We are certain that AF12-30-01-14 will meet your standards and become an essential element of your apparatus for just 28.25 €.

Customer Queries about 1SBL157001R1401:

Recently viewed
1SBL157001R1401 - ABB
AF12-30-01-14
23,15 € excl. VAT
28,71 € incl. VAT
Pending restock