All categories
Compare Cart

1SBH137001R1222 - NF22E-12 - ABB

Expected in 2-4 weeks
1SBH137001R1222 - NF22E-12 - ABB - NF22E-12 - ABB - 0
1SBH137001R1222 - NF22E-12 - ABB
21,41 € excl. VAT
26,12 € incl. VAT
Text About:
NF22E-12 - ABB
26,12 €
SPECIFICATIONS
Additional Information
Bv certificate BV_2634H24899B0
E-number (sweden) 3211447
Eclass V11.0 : 27371003
Package level 1 depth / length 79 mm
Product net depth / length 77
mm
Rohs status Following EU Directive 2011/65/EU
Mounting by screws (not supplied) 2 x M4 screws placed diagonally
Resistance to vibrations acc 5 ... 300 Hz 4 g closed position / 2 g open position
Main
Terminal type Screw Terminals
degree of protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Complementary
Ambient air temperature Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Ccc certificate 2020980303000185
Declaration of conformity - ce 1SBD250005U1000
Package level 1 gross weight 0.27 kg
Product net weight 0.27
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000196 - Contactor relay
Etim 5 EC000196 - Contactor relay
Package level 1 height 47 mm
Product net width 45
mm
Cb certificate CB_SE-93051M2
Package level 1 units box 1 piece
Connecting capacity auxiliary circuit ul/csa Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Connecting capacity control circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Package level 1 width 87 mm
Package level 2 depth / length 300 mm
Cqc certificate CQC2019010303267993
Environmental information 1SBD250151E1000


1SBC100222M0201
Package level 2 gross weight 14.58 kg
Package level 2 height 315 mm
Idea granular category code (igcc) 4763 >> Power contactor, DC switching
Package level 2 units box 27 piece
Dnv gl certificate DNV-GL_TAE00001BV-3
Instructions and manuals 1SBC101027M6801
Number of auxiliary contacts no 2
Package level 2 width 250 mm
Package level 3 units 1296 piece
Maximum operating altitude permissible Without Derating 3000 m
Gl certificate DNV-GL_TAE00001BV-3
Minimum order quantity 1 piece
Maximum mechanical switching frequency 6000 cycles per hour
wire stripping length Auxiliary Circuit 10 mm
Control Circuit 10 mm
Object classification code K
Package level 1 ean 3471523100121
Product net height 86
mm
Rated control circuit voltage (uc) 50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Rated short-time withstand current low voltage (icw) for 0.1 s 140 A
for 1 s 100 A
Rated frequency (f) Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Rated impulse withstand voltage (uimp) 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Operate time Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Rated operational current ac-15 (ie) (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated operational current dc-13 (ie) (24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated operational voltage Auxiliary Circuit 690 V
Reach declaration 2CMT2021-006202
Resistance to shock acc Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Tightening torque ul/csa Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Ul certificate UL_20180227_E252354_2_1
Ul listing card UL_E252354
Environment
Climatic withstand Category B according to IEC 60947-1 Annex Q
Connecting capacity auxiliary circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Conventional free-air thermal current (ith) acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Customs tariff number 85364900
EAC certificate EAC_RU C-FR ME77 B03544
Rina certificate RINA_ELE240318XG
Declaration of conformity - ccc CQC2011010303465426
ETIM - 8 EC000196 - Contactor relay
Etim 6 EC000196 - Contactor relay
Gost certificate GOST_POCCFR.ME77.B06804.pdf
Rmrs certificate RMRS_1802702280
standards IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Declaration of conformity - ukca 1SBD250036U1000
Etim 7 EC000196 - Contactor relay
Kc certificate KC-HW02016-21031A
Dnv certificate DNV-GL_TAE00001BV-3
Lr certificate LRS_C1400038
E-number (finland) 3706400
Number of auxiliary contacts nc 2
Rohs information 2CMT2021-006277
Maximum electrical switching frequency (AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Unspsc 39121529
Recently viewed
21,41 € excl. VAT
26,12 € incl. VAT