Complementary
Ambient air temperature
Operation -25 ... +55 °C
Operation Compensated -25 ... +55 °C
Storage -40 ... +70 °C
Declaration of conformity - ce
1SAD938518-0043
Package level 1 gross weight
1.02 kg
Product net weight
0.77
kg
suitable for
A145
A185
AF145
AF185
AF190
AF205
Cad dimensional drawing
2CDC001079B0201
Etim 4
EC000106 - Thermal overload relay
Etim 5
EC000106 - Thermal overload relay
Package level 1 height
133 mm
Product net width
104
mm
Ambient air temperature compensation
Yes
Cb certificate
1SAA941004-2003
Package level 1 units
1 piece
Connecting capacity auxiliary circuit ul/csa
Flexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
Package level 1 width
165 mm
tightening torque
Auxiliary Circuit 1 ... 1.3 N·m
Main Circuit 25 N·m
Connecting capacity main circuit
Hole Diameter > 10 mm²
Rigid or Flexible with Cable Lug 1x 25 ... 120 mm²
dimension
1SAZ400401F0001
Package level 2 depth / length
395 mm
Package level 2 ean
4013614494277
Cqc certificate
CQC2016010309922936
Environmental information
1SAC200056H0009
Package level 2 gross weight
8.786 kg
Package level 2 height
210 mm
Contact rating ul/csa
(NC:) B600
(NO:) C600
Idea granular category code (igcc)
5366 >> Thermal overload relay
Package level 2 units
4 piece
Dnv gl certificate
1SAA941000-0304
Instructions and manuals
2CDC106028M6802
Number of auxiliary contacts no
1
Package level 2 width
280 mm
Maximum operating altitude permissible
2000 m
Maximum operating voltage ul/csa
Main Circuit 600 V AC
Gl certificate
1SAA941000-0304
Minimum order quantity
1 piece
wire stripping length
Auxiliary Circuit 9 mm
Instructions and manuals (part 2)
1SAC200017M0002
Object classification code
F
Package level 1 ean
4013614286056
Pollution degree
3
Product net height
151
mm
mounting position
1 ... 6
Rated frequency (f)
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Rated impulse withstand voltage (uimp)
Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated insulation voltage (ui)
690 V
Power loss
at Rated Operating Conditions per Pole 3.8 ... 6.9 W
Rated operational current ac-15 (ie)
(120 V) NC 3 A
(120 V) NO 1.5 A
(240 V) NC 3 A
(240 V) NO 1.5 A
(400 V) NC 1.9 A
(400 V) NO 1 A
(440 V) NC 1 A
(440 V) NO 1 A
(500 V) NC 1 A
(500 V) NO 1 A
Rated operational current dc-13 (ie)
(125 V) NC 0.25 A
(125 V) NO 0.25 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.12 A
(250 V) NO 0.04 A
(60 V) NC 0.25 A
(60 V) NO 0.25 A
Rated operational voltage
Auxiliary Circuit 440 V DC
Auxiliary Circuit 500 V AC
Main Circuit 690 V AC
Main Circuit 440 V DC
Poles description
3
Recommended screw driver
Auxiliary Circuit Pozidriv 1
Main Circuit Open Bars
Rated operational current (ie)
175 A
Resistance to shock acc
11 ms Pulse 12g
Tightening torque ul/csa
Auxiliary Circuit 12 in·lb
Main Circuit 220 in·lb
Ul certificate
E48139-19910930
Setting range
130 ... 175 A
Time-current characteristic curve
1SAZ400502F0005
Environment
Connecting capacity auxiliary circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Conventional free-air thermal current (ith)
Auxiliary Circuit NC 5 A
Auxiliary Circuit NO 5 A
Customs tariff number
85364900
EAC certificate
1SAA941002-2702
Connecting capacity main circuit ul/csa
Flexible 1x 4-0000 AWG
Stranded 1x 4-0000 AWG
Declaration of conformity - ccc
2020980304001321
ETIM - 8
EC000106 - Thermal overload relay
Etim 6
EC000106 - Thermal overload relay
Rmrs certificate
1SAA941000-0704
standards
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Declaration of conformity - ukca
1SAD938501-1043
Etim 7
EC000106 - Thermal overload relay
Dnv certificate
1SAA941000-0304
Lr certificate
1SAA941000-0504
E-number (finland)
3709361
Number of auxiliary contacts nc
1
Rohs information
1SAD938518-0043
Unspsc
39122330