MO496-90 Manual Motor Starter - ABB
SPECIFICATIONS
Additional Information
Data sheet, technical information 1SBC100173C0201
Eclass V11.0 : 27370401
Package level 1 depth / length 190 mm
Product net depth / length 174
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Remarks For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Main
degree of protection Housing IP20
Main Circuit Terminals IP00
Complementary
Actuator type Rotary Handle
Ambient air temperature Operation -20 ... +70 °C
Storage -50 ... +80 °C
Declaration of conformity - ce 1SAD938505-0051
Package level 1 gross weight 2.3 kg
Product net weight 2.266
kg
Etim 4 EC000074 - Motor protective circuit-breaker
Etim 5 EC000074 - Motor protective circuit-breaker
Package level 1 height 171 mm
Product net width 70
mm
[ics] rated service breaking capacity (230 V AC) 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 5 kA
(690 V AC) 3 kA
Ambient air temperature compensation No
Package level 1 units 1 piece
Package level 1 width 76.5 mm
tightening torque Main Circuit 4 ... 6 N·m
Connecting capacity main circuit Flexible with Ferrule 1x 2.5 ... 50 mm²
Flexible with Ferrule 2x 2.5 ... 35 mm²
Solid 1/2x 2.5 ... 16 mm²
Stranded 1x 10 ... 70 mm²
Stranded 2x 10 ... 50 mm²
Contact position indication ON / OFF / TRIP
Horsepower rating ul/csa (200 V AC) Three Phase 30 Hp
(208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
Idea granular category code (igcc) 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Instructions and manuals 1SAM507001R1001
Maximum operating altitude permissible 2000 m
Maximum operating voltage ul/csa Main Circuit 600 V AC
Minimum order quantity 1 piece
wire stripping length Main Circuit 17 mm
mechanical durability 50000 cycle
Object classification code F
electrical durability 25000 cycle
Package level 1 ean 4013614265822
Pollution degree 3
Product net height 165
mm
mounting position 1 ... 6
Rated frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Rated impulse withstand voltage (uimp) Main Circuit 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) 690 V
Rated operational current ac-3 (ie) 90 A
Power loss at Rated Operating Conditions per Pole 10 W
Rated operational power ac-3 (pe) (400 V) Three Phase 45 kW
Rated operational voltage Main Circuit 690 V AC
Main Circuit 450 V DC
Rated instantaneous short-circuit current setting (ii) 1170 A
Poles description 3
Recommended screw driver Hexagon 4
Rated operational current (ie) 90 A
Resistance to shock acc 11 ms Pulse 25g
Tightening torque ul/csa Main Circuit 35 ... 53 in·lb
Ul certificate UL_E167205
Rated ultimate short-circuit breaking capacity (icu) (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 70 kA
(500 V AC) 10 kA
(690 V AC) 10 kA
Setting range None
Environment
Conventional free-air thermal current (ith) Main Circuit 90 A
Customs tariff number 85362090
EAC certificate 1SAA937001-2703
Connecting capacity main circuit ul/csa Flexible 1x 10-2/0 AWG
Flexible 1/2x 10-1/0 AWG
Stranded 1x 10-2/0 AWG
Stranded 1/2x 10-1/0 AWG
Cul certificate 1SAA937000-1701
Declaration of conformity - ccc 2022960307001586
ETIM - 8 EC000074 - Motor protection circuit-breaker
Etim 6 EC000074 - Motor protection circuit-breaker
Rmrs certificate 1SAA918000-0704
standards CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 508
Declaration of conformity - ukca 1SAD938500-1051
Etim 7 EC000074 - Motor protection circuit-breaker
General use rating ul/csa (600 V AC) 90 A
Dnv certificate 1SAA937000-0301
Rohs information 1SAD938505-0051
Unspsc 39121521