SPECIFICATIONS
Additional Information
Bv certificate 1SAA963001-0202
Data sheet, technical information 2CDC131021D0202
E-number (sweden) 3112125
Eclass V11.0 : 27370401
Package level 1 depth / length 95 mm
Cut-off current characteristic 1SAM300508F0001


1SAM300508F0003
Product net depth / length 86.75
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Remarks UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Resistance to vibrations acc 5g / 3 ... 150 Hz
Main
Terminal type Screw Terminals
i²t at switch-on 1SAM300507F0001


1SAM300507F0003
degree of protection Housing IP20
Main Circuit Terminals IP10
Complementary
Actuator type Rotary Handle
Ambient air temperature Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Declaration of conformity - ce 1SAD101100-3402
Package level 1 gross weight 0.28 kg
Product net weight 0.265
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000074 - Motor protective circuit-breaker
Etim 5 EC000074 - Motor protective circuit-breaker
Package level 1 height 50 mm
Product net width 45
mm
[ics] rated service breaking capacity (230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
Ambient air temperature compensation Yes
Cb certificate 1SAA963002-2002
Package level 1 units box 1 piece
Package level 1 width 92 mm
tightening torque Main Circuit 0.8 ... 1.2 N·m
Connecting capacity main circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
dimension 1SAM300402F0001
Package level 2 depth / length 395 mm
Package level 2 ean 4013614408991
Cqc certificate CQC2010010307387700


CQC2019010307243864
Contact position indication ON / OFF / TRIP
Environmental information 1SAC200049H0009
Package level 2 gross weight 11.586 kg
Horsepower rating ul/csa (200 V AC) Three Phase 1 Hp
(208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
Package level 2 height 210 mm
Idea granular category code (igcc) 4731 >> Manual Starters
Package level 2 units carton 40 piece
Dnv gl certificate 1SAA963001-0304
Instructions and manuals 2CDC131022M6802
Package level 2 width 280 mm
Maximum operating altitude permissible 2000 m
Maximum operating voltage ul/csa Main Circuit 600 V AC
Full load amps motor use (200 V AC) Three Phase 6.3 A
(208 V AC) Three Phase 6.3 A
(220 ... 240 V AC) Three Phase 6.3 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 6.1 A
Minimum order quantity 1 piece
Iecex certificate 1SAA963000-4001
wire stripping length Main Circuit 9 mm
Instructions and manuals (part 2) 2CDC131060M0202
mechanical durability 100000 cycle
Object classification code F
electrical durability 50000 cycle
Locked rotor amps (200 V AC) Three Phase 37.8 A
(208 V AC) Three Phase 37.8 A
(220 ... 240 V AC) Three Phase 37.8 A
(440 ... 480 V AC) Three Phase 32 A
(550 ... 600 V AC) Three Phase 36.8 A
Package level 1 ean 4013614400094
Pollution degree 3
Product net height 90
mm
Minimum mounting distance Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
mounting position 1 ... 6
Rated frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Rated impulse withstand voltage (uimp) Main Circuit 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) 690 V
Rated operational current ac-3 (ie) 6.3 A
Power loss at Rated Operating Conditions per Pole 0.7 ... 1.8 W
Rated operational power ac-3 (pe) (400 V) Three Phase 2.2 kW
Rated operational voltage Main Circuit 690 V AC
Main Circuit 250 V DC
Rated instantaneous short-circuit current setting (ii) 78.8 A
Reach declaration 1SAA960005-4502
Poles description 3
Recommended screw driver Pozidriv 2
Rated operational current (ie) 6.3 A
Resistance to shock acc 11 ms Pulse 25g
Rated operational current ac-3e (ie) 6.3 A
Rated operational current dc-5 (ie) 6.3 A
Tightening torque ul/csa Main Circuit 10 ... 12 in·lb
Rated operational power ac-3e (pe) (400 V) Three Phase 2.2 kW
Ul certificate E137861-20090225


E345003-20090225
Rated ultimate short-circuit breaking capacity (icu) (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
Setting range 4.0 ... 6.3 A
Short-circuit current rating (sccr) Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Time-current characteristic curve 1SAM300505F0009
Environment
Atex certificate 1SAA963000-3902
Conventional free-air thermal current (ith) Main Circuit 6.3 A
Customs tariff number 85362010
EAC certificate 1SAA963000-2701
Rina certificate 1SAA963002-0802
Connecting capacity main circuit ul/csa Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Declaration of conformity - ccc 2020980307003526


2020980307003041
ETIM - 8 EC000074 - Motor protection circuit-breaker
Etim 6 EC000074 - Motor protection circuit-breaker
Rmrs certificate 1SAA918000-0704
standards IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Declaration of conformity - ukca 1SAD201100-3402
Etim 7 EC000074 - Motor protection circuit-breaker
General use rating ul/csa (600 V AC) 6.3 A
Kc certificate 1SAA963002-1502
Ex operating instructions 2CDC131063M6801
Lr certificate 1SAA963001-0502
E-number (finland) 3705993
Rohs information 1SAA963006-4502
Unspsc 39121521
Recently viewed