All categories
Compare Cart

1SAM340000R1008 - MS132-4.0T Circuit-breaker for primary - ABB

Expected in 2-4 weeks
1SAM340000R1008 - MS132-4.0T Circuit-breaker for primary - ABB - MS132-4.0T Circuit-breaker for primary - ABB - 0
1SAM340000R1008 - MS132-4.0T Circuit-breaker for primary - ABB
38,21 € excl. VAT
46,61 € incl. VAT
Text About:
MS132-4.0T Circuit-breaker for primary - ABB
46,61 €
SPECIFICATIONS
Additional Information
Data sheet, technical information 2CDC131058D0201
Eclass V11.0 : 27370409
Package level 1 depth / length 95 mm
Product net depth / length 86.75
mm
Rohs status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Resistance to vibrations acc 5g / 3 ... 150 Hz
Main
Terminal type Screw Terminals
i²t at switch-on 1SAM300517F0001
degree of protection Housing IP20
Main Circuit Terminals IP10
Complementary
Actuator type Rotary Handle
Ambient air temperature Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Declaration of conformity - ce 1SAD101100-3404
Package level 1 gross weight 0.28 kg
Product net weight 0.265
kg
Cad dimensional drawing 2CDC001079B0201
Etim 4 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
Etim 5 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
Package level 1 height 50 mm
Product net width 45
mm
[ics] rated service breaking capacity (230 V AC) 100 kA
(400 V AC) 100 kA
Ambient air temperature compensation Yes
Package level 1 units box 1 piece
Package level 1 width 92 mm
tightening torque Main Circuit 0.8 ... 1.2 N·m
Connecting capacity main circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
dimension 1SAM300402F0001
Package level 2 depth / length 395 mm
Package level 2 ean 4013614487187
Cqc certificate CQC2010010307387700
Contact position indication ON / OFF / TRIP
Environmental information 1SAC200049H0009
Package level 2 gross weight 11.586 kg
Horsepower rating ul/csa (120 V AC) Single Phase 0.13 Hp
(220 ... 240 V AC) Single Phase 0.33 Hp
Package level 2 height 210 mm
Idea granular category code (igcc) 4864 >> Enclosed 3 Pole Circuit Breakers
Package level 2 units carton 40 piece
Instructions and manuals 2CDC131057M6801
Package level 2 width 280 mm
Maximum operating altitude permissible 2000 m
Maximum operating voltage ul/csa Main Circuit 600 V AC
Full load amps motor use (120 V AC) Single Phase 4 A
(220 ... 240 V AC) Single Phase 4 A
Minimum order quantity 1 piece
wire stripping length Main Circuit 9 mm
Instructions and manuals (part 2) 2CDC131060M0202
mechanical durability 100000 cycle
Object classification code F
electrical durability 50000 cycle
Locked rotor amps (120 V AC) Single Phase 24 A
(220 ... 240 V AC) Single Phase 24 A
Package level 1 ean 4013614484988
Pollution degree 3
Product net height 90
mm
Minimum mounting distance Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 9 mm
Other Device Same Type, Vertical 150 mm
mounting position 1 ... 6
Rated frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Rated impulse withstand voltage (uimp) Main Circuit 6 kV
Mounting on din rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui) 690 V
Power loss at Rated Operating Conditions per Pole 0.6 ... 1.5 W
Rated operational voltage Main Circuit 690 V AC
Rated instantaneous short-circuit current setting (ii) 80 A
Reach declaration 1SAA963005-4502
Poles description 3
Recommended screw driver Pozidriv 2
M3.5
Rated operational current (ie) 4 A
Resistance to shock acc 11 ms Pulse 25g
Tightening torque ul/csa Main Circuit 10 ... 12 in·lb
Ul certificate E137861-20090225
Rated ultimate short-circuit breaking capacity (icu) (400 V AC) 100 kA
Setting range 2.5 ... 4.0 A
Short-circuit current rating (sccr) Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Time-current characteristic curve 1SAM300535F0008
Environment
Conventional free-air thermal current (ith) Main Circuit 4 A
Customs tariff number 85362010
Connecting capacity main circuit ul/csa Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Declaration of conformity - ccc 2020980307003526
ETIM - 8 EC000228 - Power circuit-breaker for trafo/generator/installation protection
Etim 6 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
Rmrs certificate 1SAA918000-0704
standards IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
Declaration of conformity - ukca 1SAD201100-3404
Etim 7 EC000228 - Power circuit-breaker for trafo/generator/installation protection
Kc certificate 1SAA963002-1502
E-number (finland) 3707277
Rohs information 1SAA963006-4502
Unspsc 39121601
Recently viewed
38,21 € excl. VAT
46,61 € incl. VAT
Expected in 2-4 weeks