Complementary
Actuator type
Rotary Handle
Ambient air temperature
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Declaration of conformity - ce
1SAD101100-3401
Package level 1 gross weight
0.28 kg
Product net weight
0.265
kg
Cad dimensional drawing
2CDC001079B0201
Etim 4
EC000074 - Motor protective circuit-breaker
Etim 5
EC000074 - Motor protective circuit-breaker
Package level 1 height
50 mm
Product net width
45
mm
[ics] rated service breaking capacity
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
Ambient air temperature compensation
Yes
Cb certificate
1SAA963005-2003
1SAA963006-2001
Package level 1 units
box 1 piece
Package level 1 width
92 mm
tightening torque
Main Circuit 0.8 ... 1.2 N·m
Connecting capacity main circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
dimension
1SAM200422F0001
Package level 2 depth / length
395 mm
Package level 2 ean
4013614408700
Cqc certificate
CQC2011010307506570
CQC2014010307744794
Contact position indication
ON / OFF
Environmental information
1SAC200050H0009
Package level 2 gross weight
11.586 kg
Horsepower rating ul/csa
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
Package level 2 height
210 mm
Idea granular category code (igcc)
4731 >> Manual Starters
Package level 2 units
carton 40 piece
Dnv gl certificate
1SAA963000-0304
Instructions and manuals
2CDC131011M6802
Package level 2 width
280 mm
Maximum operating altitude permissible
2000 m
Maximum operating voltage ul/csa
Main Circuit 600 V AC
Full load amps motor use
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
Gl certificate
1SAA963000-0402
Minimum order quantity
1 piece
wire stripping length
Main Circuit 9 mm
Instructions and manuals (part 2)
2CDC131060M0202
mechanical durability
100000 cycle
Object classification code
F
electrical durability
100000 cycle
Locked rotor amps
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
Package level 1 ean
4013614320330
Pollution degree
3
Product net height
90
mm
Minimum mounting distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
mounting position
any; 1 ... 6
Rated frequency (f)
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated impulse withstand voltage (uimp)
Main Circuit 6 kV
Mounting on din rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Rated insulation voltage (ui)
690 V
Rated operational current ac-3 (ie)
10 A
Power loss
at Rated Operating Conditions per Pole 0.9 ... 2.4 W
Rated operational power ac-3 (pe)
(400 V) Three Phase 4 kW
Rated operational voltage
Main Circuit 690 V AC
Rated instantaneous short-circuit current setting (ii)
150 A
Reach declaration
1SAA960005-4502
Poles description
3
Recommended screw driver
Pozidriv 2
Rated operational current (ie)
10 A
Resistance to shock acc
11 ms Pulse 25g
Rated operational current ac-3e (ie)
10 A
Tightening torque ul/csa
Main Circuit 10 in·lb
Rated operational power ac-3e (pe)
(400 V) Three Phase 4 kW
Ul certificate
E137861-20001218
Rated ultimate short-circuit breaking capacity (icu)
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
Setting range
6.3 ... 10 A
Short-circuit current rating (sccr)
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Time-current characteristic curve
1SAM200505F0010
Environment
Conventional free-air thermal current (ith)
Main Circuit 10 A
Customs tariff number
85362010
EAC certificate
1SAA963000-2701
Connecting capacity main circuit ul/csa
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Declaration of conformity - ccc
2020980307003705
2020980307003043
ETIM - 8
EC000074 - Motor protection circuit-breaker
Etim 6
EC000074 - Motor protection circuit-breaker
Rmrs certificate
1SAA918000-0704
standards
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Declaration of conformity - ukca
1SAD201100-3401
Etim 7
EC000074 - Motor protection circuit-breaker
General use rating ul/csa
(600 V AC) 10 A
Kc certificate
1SAA963000-1501
Dnv certificate
1SAA963000-0304
Lr certificate
1SAA963000-0505
E-number (finland)
3706010
Rohs information
1SAA963006-4502
Unspsc
39121521