Complementary
Ambient air temperature
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Declaration of conformity - ce
1SAD938506-0302
Package level 1 gross weight
0.41 kg
Product net weight
0.41
kg
Cad dimensional drawing
2CDC001079B0201
Etim 5
EC001653 - Installation contactor for distribution board
Package level 1 height
69.5 mm
Product net width
54
mm
Cb certificate
1SAA920005-2001
Package level 1 units
1 piece
Connecting capacity control circuit
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Package level 1 width
92 mm
tightening torque
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Connecting capacity main circuit
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Package level 2 depth / length
395 mm
Package level 2 ean
4013614539534
Cqc certificate
CQC2017010304993562
Environmental information
1SAC200064H0009
Package level 2 gross weight
14.5 kg
Package level 2 height
210 mm
Idea granular category code (igcc)
4759 >> Installation contactor for distribution board
Package level 2 units
34 piece
Instructions and manuals
2CDC103043M6801
Package level 2 width
280 mm
Maximum operating altitude permissible
2000 m
Minimum order quantity
1 piece
Number of main contacts nc
1
wire stripping length
Control Circuit 7 mm
Main Circuit 13 mm
mechanical durability
1000000 cycle
Number of main contacts no
3
Object classification code
Q
electrical durability
AC-1 (NO) 150000 cycle
AC-3 (NO) 150000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 150000 cycle
Package level 1 ean
4013614525131
Pollution degree
3
Product net height
85
mm
Rated control circuit voltage (uc)
230 V
Rated frequency (f)
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated impulse withstand voltage (uimp)
4 kV
Rated insulation voltage (ui)
500 V
Rated operational current ac-1 (ie)
(NC) 30 A
(NO) 40 A
Rated operational current ac-3 (ie)
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
Rated operational current ac-7a (ie)
(NO) 40 A
Rated operational current ac-7b (ie)
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
Rated operational power ac-1 (pe)
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
Rated operational power ac-3 (pe)
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
Rated operational power ac-7a (pe)
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
Rated operational power ac-7b (pe)
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
Rated operational voltage
Main Circuit 220 V DC
Main Circuit 400 V AC
Reach declaration
2CMT2021-006202
Poles description
4
Recommended screw driver
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Resistance to shock acc
11 ms Pulse 15g
Environment
Customs tariff number
85365080
EAC certificate
1SAA920001-2702
Declaration of conformity - ccc
2020980304001310
ETIM - 8
EC001653 - Installation contactor for distribution board
Etim 6
EC001653 - Installation contactor for distribution board
Rmrs certificate
1SAA920000-0705
Declaration of conformity - ukca
1SAD938501-1302
Etim 7
EC001653 - Installation contactor for distribution board
Width in number of modular spacings
3
E-number (finland)
3707813
Rohs information
2CMT2021-006277
Unspsc