SPECIFICATIONS
Main
reverse polarity protection Internal
Complementary
Absolute accuracy error +/- 0.13 % full scale 25 °C 1...5 V
+/- 0.19 % full scale 60 °C 1...5 V
+/- 0.21 % full scale 25 °C +/- 5 V
+/- 0.26 % full scale 60 °C +/- 5 V
+/- 0.27 % full scale 25 °C +/- 10 V
+/- 0.27 % full scale 25 °C 4...20 mA
+/- 0.32 % full scale 25 °C +/- 20 mA
+/- 0.32 % full scale 60 °C +/- 10 V
+/- 0.38 % full scale 60 °C 4...20 mA
+/- 0.41 % full scale 60 °C +/- 20 mA
Product certifications FM Class 1 Division 2
CSA
UL
Analogue input range +/- 20 mA 14 bits + sign 250 kOhm
4...20 mA 15 bits + sign 250 kOhm
+/- 10 V 14 bits + sign > 0.1 kOhm
+/- 5 V 14 bits + sign > 0.1 kOhm
1...5 V 15 bits + sign > 0.1 kOhm
data formats Full 16 bits signed
Handle front plate colour 125 mm
Product or component type Analogue input base
marking CE
Analogue input number 8
Common mode rejection > 80 dB between channels to ground
Analogue input type Differential
width (w) 141.5 mm
Local signalling 1 LED (green) for ready
8 LEDs for channel status
External power requirement < 382 mA DC
20.4...28.8 V DC
24 V DC
Net weight 0.215 kg
Isolation between channels +/- 200 V DC for 1 minute
Isolation between channels and bus 500 V AC for 1 minute
Isolation between channels and ground 500 V AC for 1 minute
depth 47.5 mm
electrical connection 2 connectors for removable terminal blocks
Permissible common mode voltage 100 V 47...63 Hz DC between channels to ground
250 V 47...63 Hz AC between channels to ground
Resistance to electrostatic discharge 4 kV contact conforming to IEC 801-2
8 kV on air conforming to IEC 801-2
conversion time 12 ms 8
Resistance to electromagnetic fields 10 V/m 80...1000 MHz conforming to IEC 801-3
Environment
Ambient air temp for storage/transportation -40…85 °C
operating altitude <= 5000 m
Range of product Modicon Momentum automation platform
ambient air temperature for operation 0…60 °C
standards EN 50081-2
IEC 1131
relative humidity 95 % without condensation
protective treatment TC